2002
DOI: 10.1016/s0894-1777(02)00163-2
|View full text |Cite
|
Sign up to set email alerts
|

Scaling of heat transfer coefficients along louvered fins

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
21
0

Year Published

2011
2011
2019
2019

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 56 publications
(23 citation statements)
references
References 10 publications
0
21
0
Order By: Relevance
“…Only five louver rows were heated: those surrounding the center row where the temperature measurements are done. It is important to heat the adjacent fin rows in order to accurately capture any thermal wake effects, as shown by Lyman et al [23]. By measuring the local air velocity (using a pitot tube) and temperature in the wake of the fin array the heat balance was verified to be within 5%.…”
Section: Transition To Unsteady Flowmentioning
confidence: 97%
See 2 more Smart Citations
“…Only five louver rows were heated: those surrounding the center row where the temperature measurements are done. It is important to heat the adjacent fin rows in order to accurately capture any thermal wake effects, as shown by Lyman et al [23]. By measuring the local air velocity (using a pitot tube) and temperature in the wake of the fin array the heat balance was verified to be within 5%.…”
Section: Transition To Unsteady Flowmentioning
confidence: 97%
“…Flow efficiency increases with Re and louver angle, while decreasing with fin pitch and thickness ratio. Local heat transfer coefficients in louvered fins presented by Lyman et al [23] showed the impact of the local thermal field surrounding a louver. If a louver is surrounded by the hot thermal wake of an upstream louver, it will have a lower heat transfer coefficient.…”
Section: Main Flow Manipulationmentioning
confidence: 99%
See 1 more Smart Citation
“…Lyman et al performed experimental studies on different louver models with varied fin pitch and louver angles over a range of Reynolds numbers. A method for evaluating spatially resolved louver heat transfer coefficients was presented [3]. Weijuan and Pingfang presenteda method to predict the coefficient of performance (COP) of the heat pump and the COPs of ground source heat pump (GSHP) system with limited parameters.…”
Section: Introductionmentioning
confidence: 99%
“…They showed that the performance advantage of the elliptical tube arrangements resulted from the higher fin efficiency [6]. Lyman et al conducted experiments in a number of large-scale louver models with varied fin pitch and louver angle over a range of Reynolds numbers [3]. Nuntaphan et al analysed the effect of inclination angle on the louver finned tube heat exchanger in natural convection condition.…”
Section: Introductionmentioning
confidence: 99%