2014
DOI: 10.1118/1.4892171
|View full text |Cite
|
Sign up to set email alerts
|

Sampling strategies for subsampled segmented EPI PRF thermometry in MR guided high intensity focused ultrasound

Abstract: Purpose: To investigate k-space subsampling strategies to achieve fast, large field-of-view (FOV) temperature monitoring using segmented echo planar imaging (EPI) proton resonance frequency shift thermometry for MR guided high intensity focused ultrasound (MRgHIFU) applications. Methods: Five different k-space sampling approaches were investigated, varying sample spacing (equally vs nonequally spaced within the echo train), sampling density (variable sampling density in zero, one, and two dimensions), and util… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
21
0

Year Published

2015
2015
2017
2017

Publication Types

Select...
6
1

Relationship

4
3

Authors

Journals

citations
Cited by 17 publications
(22 citation statements)
references
References 64 publications
0
21
0
Order By: Relevance
“…The KWIC window used to reconstruct nearly all KWIC images in this work had 13 projections in the center, and each successive ring used the next higher Fibonacci number of projections up to 377 in the outermost ring. The outer radius of each ring (as a fraction of the total radius) was determined by the ratio of the number of projections in the ring and the number in the outermost ring: (13,21,34,55,89,144, 233, 377)/377 ¼ (0.035, 0.056, 0.09, 0.146, 0.236, 0.382, 0.618, 1). The sliding window was advanced 13 projections between each reconstructed time point.…”
Section: Image Reconstructionmentioning
confidence: 99%
See 1 more Smart Citation
“…The KWIC window used to reconstruct nearly all KWIC images in this work had 13 projections in the center, and each successive ring used the next higher Fibonacci number of projections up to 377 in the outermost ring. The outer radius of each ring (as a fraction of the total radius) was determined by the ratio of the number of projections in the ring and the number in the outermost ring: (13,21,34,55,89,144, 233, 377)/377 ¼ (0.035, 0.056, 0.09, 0.146, 0.236, 0.382, 0.618, 1). The sliding window was advanced 13 projections between each reconstructed time point.…”
Section: Image Reconstructionmentioning
confidence: 99%
“…3D MR thermometry can overcome many of the FOV, partial volume, and coverage gap limitations, which are inherent in 2D imaging but unfortunately, standard 3D sequences typically require too much time to acquire kspace to be clinically viable. Temporal resolution can be increased by methods involving undersampling, such as temporally constrained reconstruction (16), model predictive filtering (17), Kalman filtering (18), parallel imaging (19), or using a sequence designed for increased speed such as segmented echo-planar imaging (seg-EPI) (20,21).…”
Section: Introductionmentioning
confidence: 99%
“…For a detailed analysis of various sampling strategies, see Ref. 24. The image reconstruction was carried out on a machine with an Intel Xeon dual six core processor with a processor speed of 2.66 GHz and memory of 64 GB.…”
Section: C Simulation and Experimentsmentioning
confidence: 99%
“…At 3 Tesla, the PRF changes 1.27 Hz/ C, so with a 29 Hz pixel BW the hot spot will shift by one pixel with a 22.7 C temperature rise; temperature increases in MRgFUS ablations are typically 20-30 C. Temperature magnitude errors also arise as hotter pixels blur into cooler pixels. Low pixel BWs in the phaseencoded dimension are also common in echo-planar imaging (EPI) sequences used to accelerate volumetric temperature scans (12)(13)(14)(15). Multishot acquisition schemes can reduce these errors to some degree, but do not eliminate them entirely (9,16).…”
Section: Introductionmentioning
confidence: 99%