2009
DOI: 10.1080/00032710902726070
|View full text |Cite
|
Sign up to set email alerts
|

Samarium(III)-PVC-Membrane Sensor Based on Ethoxy-1-ethoxycarbonyl-1,2-dihydroquinoline

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
12
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 32 publications
(12 citation statements)
references
References 57 publications
0
12
0
Order By: Relevance
“…The effect of membrane ingredients on the properties of the membrane electrodes, including the effect of the plasticizer, the plasticizer/PVC ratio, the nature and amount of ionophore, and especially, the nature and amount of the additives used, have been reported to significantly influence the behavior of ion-selective electrodes [43][44][45][46][47]. These were hence studied for the TPTA-based Sm 3+ -selective membrane and the results are given in Table 1.…”
Section: The Membrane Composition Influencementioning
confidence: 99%
See 1 more Smart Citation
“…The effect of membrane ingredients on the properties of the membrane electrodes, including the effect of the plasticizer, the plasticizer/PVC ratio, the nature and amount of ionophore, and especially, the nature and amount of the additives used, have been reported to significantly influence the behavior of ion-selective electrodes [43][44][45][46][47]. These were hence studied for the TPTA-based Sm 3+ -selective membrane and the results are given in Table 1.…”
Section: The Membrane Composition Influencementioning
confidence: 99%
“…Due to this fact that the nature of the used plasticizer, influencing the dielectric constant of the membrane phase, the mobility of the ionophore molecules, and the state of ligand [43][44][45][46][47], affects the properties of the ISE membranes; i.e. the selectivity, working concentration range, and response time of the membrane electrode, for different solvent mediators (NB, AP, BA, and DBP) were tested.…”
Section: The Membrane Composition Influencementioning
confidence: 99%
“…A Pyrex tube (3-5 mm o.d. on top) was dipped into the mixture for about 5s, so that a transparent membrane of about 0.3 mm thickness was formed [19][20][21][22][23][24][25][26][27] . The tube was pulled out from the mixture and kept at room temperature for 12 h. The tube was then filled with an internal solution (1.0×10 -3 M EuCl 3 ).…”
Section: Pvc Membrane Electrode Preparationmentioning
confidence: 99%
“…[22][23][24][25][26][27][28][29][30][31][32][33][34] The tube, now having a layer of the membrane on the tip were next kept at room temperature for 12 h before being filled with an internal filling solution (1.0×10 -3 mol L -1 of the target ion) and conditioned for 24 h in a 1.0×10 -2 mol L -1 solution of the target ion. To do this, the tips of the tubes were dipped into the mixture for a short time.…”
Section: Electrode Preparationmentioning
confidence: 99%