Salvage of Infected Cardiac Implantable Electrical Devices with Subpectoral Plane Pocket Revision

Abstract: Introduction Infection of cardiac implantable electrical devices (CIEDs) may lead to serious complications. Complete CIED explantation is expensive, requires expertise, not free from complications, and may not be an option in patients with device dependence. Aim To highlight that carefully selected infected CIEDs can be salvaged by placing the device in a subpectoral pocket below the pectoralis major muscle. We conducted a retrospective descriptive observational study. Material and Methods … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 32 publications
0
2
0
Order By: Relevance
“…On the one hand, device explantation 3 has increased globally as the prevalence of patients using pacemakers, implantable cardioverter defibrillators, and cardiac resynchronization devices has increased. 1,2 who are at risk of device complications [5][6][7][8] requiring removal while on the other hand box change 4,9 and reuse of all properly functioning intravascular leads is a common practice in cardiology. 27 The difficulty in lead extraction is proportional to the indwelling time of the leads because of increasing fibrosis around areas of contact between the lead and surrounding vasculature and myocardium.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…On the one hand, device explantation 3 has increased globally as the prevalence of patients using pacemakers, implantable cardioverter defibrillators, and cardiac resynchronization devices has increased. 1,2 who are at risk of device complications [5][6][7][8] requiring removal while on the other hand box change 4,9 and reuse of all properly functioning intravascular leads is a common practice in cardiology. 27 The difficulty in lead extraction is proportional to the indwelling time of the leads because of increasing fibrosis around areas of contact between the lead and surrounding vasculature and myocardium.…”
Section: Discussionmentioning
confidence: 99%
“…With increasing volume of implantation of devices in cardiology 1 the number of explantation 2 and reimplantation of devices also increasing linearly. 3 This may be due to complication like lead or device erosion 5 , insulation break 4 , lead fracture 5 and infection on the site of implantation 6 or it may be due to depletion of pulse generator. 7 In case of erosion or infection of the device and leads, the whole hardware needs to be explanting all together.…”
Section: Introductionmentioning