2021
DOI: 10.1088/1755-1315/833/1/012070
|View full text |Cite
|
Sign up to set email alerts
|

Salt weathering and ultrasonic pulse velocity: condition assessment of salt damaged porous limestone

Abstract: Salt weathering is one of the crucial causes of building stone decay. For assessing the durability of stones against salt weathering, a standardised test procedure (EN 12370:2020 Determination of resistance to salt crystallisation) is used: the mass loss of the stone is measured during sodium sulphate crystallisation cycles. Porous, Miocene limestone test specimens collected from the Sóskút quarry (Hungary) were subjected to salt crystallisation cycles in laboratory conditions. The limestone with open porositi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 13 publications
0
4
0
Order By: Relevance
“…The Geotron was able to measure S wave velocity in addition to P wave velocity, which the Pundit could not. The study used a modified version of the post-processing method developed by Benavente et al [14] for Geotron signals, which was further modified for the purpose of this study [15].…”
Section: Methodsmentioning
confidence: 99%
“…The Geotron was able to measure S wave velocity in addition to P wave velocity, which the Pundit could not. The study used a modified version of the post-processing method developed by Benavente et al [14] for Geotron signals, which was further modified for the purpose of this study [15].…”
Section: Methodsmentioning
confidence: 99%
“…The ultrasonic measurement was performed with Geotron device (frequency of 80 kHz). P and S waves velocities from Geotron were analysed based on Rozgonyi-Boissinot et al [23]. In this study, dynamic modulus of elasticity (E dyn ) and Poisson ratio were calculated as a function of P and S waves velocities and density (Eqs.…”
Section: Methodsmentioning
confidence: 99%
“…In the present study, it was conducted using the PUNDIT device (Portable Ultrasonic Non-destructive Digital Indicating Tester) based on the ASTM C597. The equipment consists of a transducer and a receiver that are linked to an electronic timing device for timing the start of a pulse generated at the transmitting transducer and its arrival at the receiver [34]. The PUNDIT-Plus digital display screen can be used to read the travel time through the specimen.…”
Section: Ultrasonic Pulse Velocity Testingmentioning
confidence: 99%