2007
DOI: 10.2116/analsci.23.171
|View full text |Cite
|
Sign up to set email alerts
|

Salicylate Ion-Selective Electrode Based on New Tetranuclear Copper Complexes of O-Vannlin-methionine as Neutral Carriers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2009
2009
2021
2021

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 15 publications
(3 citation statements)
references
References 44 publications
0
3
0
Order By: Relevance
“…29 The membrane composition, properties of the employed solvent mediator and the plasticizer/PVC ratio are important criteria that affect both the selectivity and sensitivity of the proposed method. 30 It is beneficial to use new fabricated electrodes with competitive characteristics in order to analyze the pharmaceutical active constituents. Achieving this goal is critical where it can be accomplished by getting use of the characteristics of the composite materials as much as possible.…”
Section: Resultsmentioning
confidence: 99%
“…29 The membrane composition, properties of the employed solvent mediator and the plasticizer/PVC ratio are important criteria that affect both the selectivity and sensitivity of the proposed method. 30 It is beneficial to use new fabricated electrodes with competitive characteristics in order to analyze the pharmaceutical active constituents. Achieving this goal is critical where it can be accomplished by getting use of the characteristics of the composite materials as much as possible.…”
Section: Resultsmentioning
confidence: 99%
“…Recently, some electrodes prepared by incorporating different metallic complexes into PVC polymeric membranes have displayed relatively high selectivity toward salicylate [15][16][17][18][19][20][21][22][23]. However, some of these sensing carriers are toxic organotin complexes [17][18][19][20], some are nonstable cobalt complexes [21] and some are difficult to be synthesized [23]. Moreover, the electrodes based on these complexes exhibited somewhat poor potential response characteristics, such as sub-or super-Nernstian slope, narrow linear range, high detection limit, slow response time and so on.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, they have wide prospect of application [6]. On the other hand, because of high bioactivity, some Schiff base com plexes derived from amino acids become the hot research topics for years [7][8][9][10][11][12]. Recently, crystal juructures relating to the complexes of nickel with gly cine, L phenylanine, and 2 hydroxyl 1 naphthalde hyde have been reported [13], whereas those of nickel(II) with 2 acetylpyridine L tryptophan have not been found in the literature.…”
Section: Introductionmentioning
confidence: 99%