Safety testing of acellular pertussis vaccines: Use of animals and 3Rs alternatives

Abstract: The current test of acellular Bordetella pertussis (aP) vaccines for residual pertussis toxin (PTx) is the Histamine Sensitization test (HIST), based on the empirical finding that PTx sensitizes mice to histamine. Although HIST has ensured the safety of aP vaccines for years, it is criticized for the limited understanding of how it works, its technical difficulty, and for animal welfare reasons. To estimate the number of mice used worldwide for HIST, we surveyed major aP manufacturers and organizations perform… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
20
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 7 publications
(20 citation statements)
references
References 51 publications
0
20
0
Order By: Relevance
“…This method provides a quantitative estimate of the PTx activity of a test vaccine relative to a PTx reference standard which has been assigned histamine sensitization units (HSU) or International Units (IU). The accepted level of PTx in test vaccines also varies by region with 0.4 HSU the level in Japan and 0.8 HSU in China (Table 1) [90,100,101,102]. The animals can then be culled once the temperature reading has taken place and thus reduce the severity of the procedure.…”
Section: Specific Tests For Ptx Toxicitymentioning
confidence: 99%
See 3 more Smart Citations
“…This method provides a quantitative estimate of the PTx activity of a test vaccine relative to a PTx reference standard which has been assigned histamine sensitization units (HSU) or International Units (IU). The accepted level of PTx in test vaccines also varies by region with 0.4 HSU the level in Japan and 0.8 HSU in China (Table 1) [90,100,101,102]. The animals can then be culled once the temperature reading has taken place and thus reduce the severity of the procedure.…”
Section: Specific Tests For Ptx Toxicitymentioning
confidence: 99%
“…Both forms of the HIST assay can be used to measure the levels of PTx activity in samples by comparing the drop in temperature, or deaths per group, for a range of doses to the responses in a reference preparation [103,104,105]. While both death and changes in body temperature have been found to be dose dependent they do not seem to be linked and the modes of action may not be the same [99,102].…”
Section: Specific Tests For Ptx Toxicitymentioning
confidence: 99%
See 2 more Smart Citations
“…However, there are major regional differences in the regulatory guidelines. 17 , 18 No internationally agreed upper limit for active PTX in pertussis ACVs exists. Only China and Japan have these kinds of defined figures, of 0.8 and 0.4 histamine sensitization units/mL (HSU/mL), respectively, based on the mouse histamine sensitization test (HIST).…”