Safety evaluation of large external fixation clamps and frames in a magnetic resonance environment

Abstract: Large orthopedic external fixation clamps and related components were evaluated for force, torque, and heating response when subjected to the strong electromagnetic fields of magnetic-resonance (MR) imaging devices. Forces induced by a 3-Tesla (T) MR scanner were compiled for newly designed nonmagnetic clamps and older clamps that contained ferromagnetic components. Heating trials were performed in a 1.5 and in a 3 T MR scanner with two assembled external fixation frames. Forces of the newly designed clamps we… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
20
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 28 publications
(20 citation statements)
references
References 63 publications
(88 reference statements)
0
20
0
Order By: Relevance
“…Conversely, an accurate representation of ||E ⃗ || in the space between the coil and the load is important when evaluating safety in patients with conductive medical devices that are partially implanted or in contact with the skin [7,23]. High temperature changes in gel were reported in presence of external devices that are in contact with the skin, such as electroencephalography leads [49][50][51], electrocardiography leads [52][53][54], catheters in interventional MRI [55,56], and orthopedics external fixators [37,57]. Data presented in this paper were normalized based on the ||B ⃗ || magnitude at the isocenter of the coil.…”
Section: Discussionmentioning
confidence: 99%
“…Conversely, an accurate representation of ||E ⃗ || in the space between the coil and the load is important when evaluating safety in patients with conductive medical devices that are partially implanted or in contact with the skin [7,23]. High temperature changes in gel were reported in presence of external devices that are in contact with the skin, such as electroencephalography leads [49][50][51], electrocardiography leads [52][53][54], catheters in interventional MRI [55,56], and orthopedics external fixators [37,57]. Data presented in this paper were normalized based on the ||B ⃗ || magnitude at the isocenter of the coil.…”
Section: Discussionmentioning
confidence: 99%
“…The agar was made out of the same saline solution with additional 2% agar as a gelling agent. The similar setup has been used and described in detail in other contexts [20]. The agar phantom prevents convection next to the RFID.…”
Section: Methodsmentioning
confidence: 99%
“…This is a test method that covers the measurement of the magnetically induced displacement force produced by the static magnetic field on medical devices. The main magnetic field gradient of the MR scanner used at the measurement point was 45 ± 2 mT/cm (= 4500 mT/m) [20]. It is located 3 cm away from the laser cross for patient positioning.…”
Section: Methodsmentioning
confidence: 99%
“…IUDs were measured in a body shaped reservoir filled with 30 liters of distilled water, 300 g of polyacrylamide (PAA) and 39.6 g of NaCl, as recently described [14, 15, 16]. The conductivity of the gel was measured as 4.7±0.4 mS/cm.…”
Section: Methodsmentioning
confidence: 99%