Safety, efficacy, predictability and stability of laser in situ keratomileusis (LASIK) with a 1000‐Hz scanning spot excimer laser

Abstract: . Purpose:  To evaluate the safety, efficacy, predictability and stability of laser in situ keratomileusis (LASIK) with a 1000‐Hz scanning spot excimer laser (Concept System 1000; WaveLight GmbH, Erlangen, Germany). Methods:  LASIK was performed on twenty eyes with myopia or myopic astigmatism (mean spherical equivalent refraction: −3.97 ± 1.72 dioptres (D); mean cylinder: −0.84 ± 0.77 D) using a microkeratome for flap creation and the Concept System 1000 for photoablation. Patients were examined preoperativel… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

2
6
0
2

Year Published

2012
2012
2016
2016

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 14 publications
(10 citation statements)
references
References 23 publications
2
6
0
2
Order By: Relevance
“…12 In our study, the overall mean efficacy index was 0.99 and safety index, 1.02. These values are comparable to those obtained after myopic LASIK with the last generation of excimer lasers [16][17][18][19][20] (Table 2). Comparisons of the data in Table 2 should be performed with caution because the data represent different samples of eyes operated on by different physicians using different technologies.…”
Section: Discussionsupporting
confidence: 90%
See 1 more Smart Citation
“…12 In our study, the overall mean efficacy index was 0.99 and safety index, 1.02. These values are comparable to those obtained after myopic LASIK with the last generation of excimer lasers [16][17][18][19][20] (Table 2). Comparisons of the data in Table 2 should be performed with caution because the data represent different samples of eyes operated on by different physicians using different technologies.…”
Section: Discussionsupporting
confidence: 90%
“…Similarly, in the study by Tsiklis et al 10 of myopic eyes that had LASIK with the same technology, 90% of eyes had an SE within G0.50 D ( Table 2). This level of refractive correction predictability is equivalent to, and in some cases better than, that reported with the last generation of excimer lasers (SE within G0.50 D in 90% of eyes or more) 10,[16][17][18][19][20] (Table 2). This excellent refractive predictability was confirmed with the defocus equivalent analysis, which was significantly reduced postoperatively (0.50 D or less in 93.3% of eyes).…”
Section: Discussionsupporting
confidence: 58%
“…[24][25][26][27][28] Regarding astigmatism, although the magnitude of refractive cylinder was reduced significantly, the power vector components did not change significantly. These results were consistent with those reported previously after LASIK by our research group 2 (95% of eyes with UDVA of 20/25 or better).…”
Section: Discussionmentioning
confidence: 95%
“…Im Zuge der Weiterentwicklung der Lasertechnologie sind über das letzte Jahrzehnt neue Laserplattformen, die sich hinsichtlich der Frequenz, des Musters und der Energie der Ablation sowie der Pulsgröße unterscheiden, eingeführt worden. Einige Studien zu Excimer-Laser-Systemen mit hohen Repetitionsraten (750 oder 1050 Hz) haben bei diesen Lasersystemen bereits über ein hohes Maß an Sicherheit, Wirksamkeit sowie Vorhersagbarkeit berichten können [8,[11][12][13][14][15]. Bei Lasersystemen mit erhöhten Repetitionsraten konnten die Spotgröße reduziert und die Pulsenergie mit dem Ziel angepasst werden, dass das Ausmaß von Komplikationen (z.…”
Section: Diskussionunclassified
“…Ins-besondere thermische Schäden am Hornhautstroma stellen eine mögliche Nebenwirkung höherer Abtragungsfrequenzen dar. Durch die Applikation multipler Laserspots in einem bestimmten Areal kann es durch kumulativen Energieeintrag zu einer Erhöhung der Temperatur kommen [11,21]. Derartige thermische Schäden können sich in Form einer erhöhten postoperativen Entzündungsreaktion undim Falle der Laser-in-situ-Keratomileusis (LASIK)auch in Form einer Trübung im Interface in der frühen postoperativen Phase manifestieren.…”
Section: Diskussionunclassified