2019
DOI: 10.1038/s41433-019-0663-0
|View full text |Cite
|
Sign up to set email alerts
|

Safety and efficacy of paediatric silicone Ahmed glaucoma valve (AGV) in adult eyes with post-VR surgery glaucoma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 23 publications
0
7
0
Order By: Relevance
“…The main internal parameters of the algorithm are shown in Table 1. According to the analysis of potential field forces in Figure 6 (A), it can be seen that the potential field forces make the AGV reach dynamic equilibrium at points (3,3), and the trajectory shows that the AGV's navigation is aborted and it cannot continue to travel to the target point. The improved algorithm, as shown in Figure 6(B), generates random target points in the unreachable area of the target, guides the AGV out of the ring obstacle and successfully plans a complete path.…”
Section: Artificial Potential Field Algorithm Simulation Experimentsmentioning
confidence: 99%
See 2 more Smart Citations
“…The main internal parameters of the algorithm are shown in Table 1. According to the analysis of potential field forces in Figure 6 (A), it can be seen that the potential field forces make the AGV reach dynamic equilibrium at points (3,3), and the trajectory shows that the AGV's navigation is aborted and it cannot continue to travel to the target point. The improved algorithm, as shown in Figure 6(B), generates random target points in the unreachable area of the target, guides the AGV out of the ring obstacle and successfully plans a complete path.…”
Section: Artificial Potential Field Algorithm Simulation Experimentsmentioning
confidence: 99%
“…Figure6 (A)shows the path planning of the traditional artificial potential field algorithm. The simulation shows that the path stays at the point(3,3) and is far away from the target point. According to the analysis of potential field forces in…”
mentioning
confidence: 93%
See 1 more Smart Citation
“…This was performed on 16 patients, and all 16 patients, adequate IOP outcome was achieved at the end of 1 year with or without additional anti-glaucoma medications (AGM). Amputation of adult implant,[ 54 ] trimming the wings of 250 mm 2 Baerveldt implant,[ 55 ] and usage of FP8 model implants[ 56 ] are other modifications proposed in the literature. Turaga et al .…”
Section: Management Of Secondary Glaucoma Post Vr Surgerymentioning
confidence: 99%
“…Turaga et al . [ 56 ] compared the safety and efficacy of FP7 and FP8 implants in eyes post VR surgeries which were associated with severe conjunctival scarring. They concluded that the use of the pediatric FP8 Ahmed glaucoma valve (AGV) in adult post-vitreoretinal surgery glaucoma eyes with severe conjunctival scarring and limited subconjunctival space resulted in reasonable IOP control compared with the standard FP7 AGV implant.…”
Section: Management Of Secondary Glaucoma Post Vr Surgerymentioning
confidence: 99%