Safety and efficacy of new integrated bipolar and ultrasonic scissors compared to conventional laparoscopic 5-mm sealing and cutting instruments

Abstract: BackgroundHemostasis is a central issue in laparoscopic surgery. Ultrasonic scissors and bipolar clamps are commonly used, with known advantages with each technique.MethodsThe prototype of new surgical scissors, delivering ultrasonically generated frictional heat energy and bipolar heat energy simultaneously (THUNDERBEAT® [TB]), was compared to ultrasonic scissors (Harmonic ACE® [HA]) and an advanced bipolar device (LigaSure® [LS]) using a pig model. As safety parameters, temperature profiles after single acti… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
75
1
7

Year Published

2013
2013
2022
2022

Publication Types

Select...
4
4
2

Relationship

0
10

Authors

Journals

citations
Cited by 115 publications
(85 citation statements)
references
References 20 publications
2
75
1
7
Order By: Relevance
“…In our early experience, one patient was readmitted after discharge because of splenic artery pseudoaneurysm, and underwent reoperation with intensive care. This type of unique complication that might result from thermal damage by the various energy device was already reported even in a previous large scale study of laparoscopic distal gastrectomy with lymph node dissection (34,35). In particular, during SIDG, use of an energy-based device should be minded with much more caution because there is no effective assistance to avoid possible thermal injury to adjacent tissues, including major vessels.…”
Section: Lymphadenectomymentioning
confidence: 92%
“…In our early experience, one patient was readmitted after discharge because of splenic artery pseudoaneurysm, and underwent reoperation with intensive care. This type of unique complication that might result from thermal damage by the various energy device was already reported even in a previous large scale study of laparoscopic distal gastrectomy with lymph node dissection (34,35). In particular, during SIDG, use of an energy-based device should be minded with much more caution because there is no effective assistance to avoid possible thermal injury to adjacent tissues, including major vessels.…”
Section: Lymphadenectomymentioning
confidence: 92%
“…Moreover, the possibility of heat damage from the ultrasonic wave surgical knife has also been pointed out (Kim et al, 2008). LigaSure TM Small Jaw could be used instead of hand ligation, because it was reported that heat damage was comparatively slight (Seehofer et al, 2012).…”
Section: Resultsmentioning
confidence: 99%
“…4). 15 Tal como verificado anteriormente, [15][16][17] existe uma distribuição relativamente ampla de BP para cada tesoura. Uma razão para esta distribuição poderá ser a tração aplicada durante ativação dos instrumentos, descrita na literatura especialmente nos dispositivos ultrassónicos, que são mais passíveis de serem influenciados por esta característica.…”