Safety analysis of optimal outriggers location in high-rise building structures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
13
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(13 citation statements)
references
References 2 publications
0
13
0
Order By: Relevance
“…A graphical A Study on Static and Dynamic Behavior of Outrigger Structural System for Tall Buildings Kiran Kamath, N. Divya, Asha U Rao T method of analysis is presented for preliminary design of outrigger truss-braced high-rise shear wall structures with nonfixed foundation conditions subject to horizontal loading. [10], documented the restraining moments of outriggers acting on the core wall and the equation of the horizontal top deflection based on a simplified outrigger model. The deformation compatibility conditions between outriggers and core wall as well as the finite rigidities of outriggers are also [12], carried out the analysis to find the optimum location for the second outrigger by changing the position of second outrigger along the height of the building and placing it in all the possible locations, i.e.…”
Section: IImentioning
confidence: 99%
“…A graphical A Study on Static and Dynamic Behavior of Outrigger Structural System for Tall Buildings Kiran Kamath, N. Divya, Asha U Rao T method of analysis is presented for preliminary design of outrigger truss-braced high-rise shear wall structures with nonfixed foundation conditions subject to horizontal loading. [10], documented the restraining moments of outriggers acting on the core wall and the equation of the horizontal top deflection based on a simplified outrigger model. The deformation compatibility conditions between outriggers and core wall as well as the finite rigidities of outriggers are also [12], carried out the analysis to find the optimum location for the second outrigger by changing the position of second outrigger along the height of the building and placing it in all the possible locations, i.e.…”
Section: IImentioning
confidence: 99%
“…(ii) In the situation of flexible outrigger, for effective control of the displacement and drift, it is recommended to put the outrigger at the upper part of the structure [7,17,18,20,45,57,61,80,81,111,177,178].…”
mentioning
confidence: 99%
“…(iii) In the situation of rigid outrigger, it is recommended to lower its position to reduce the drift [45,57,61,177].…”
mentioning
confidence: 99%
See 2 more Smart Citations