Ruptura e recrescimento de flocos em água com substâncias húmicas aquáticas coagulada com sulfato de alumínio e cloreto férrico

Abstract: Aos meus pais Ricardo e Norma, meus irmãos Bruno e Gabriel e toda minha família, que durante todos estes anos foi meu porto seguro, sempre me apoiando e incentivando. Ao Professor Luiz Di Bernardo, por sua instrução e orientação para que este trabalho fosse encaminhado da melhor forma possível. Ao grande amigo Paulo Voltan pela preciosa colaboração sempre com disposição e muita amizade. À Angela Di Bernardo Dantas, cuja ajuda foi imprescindível para a realização da pesquisa. Aos amigos e colegas que ajudaram a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
1
0
1

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(7 citation statements)
references
References 2 publications
(4 reference statements)
0
1
0
1
Order By: Relevance
“…It can be identified in Figure 3-A, with Vs = 1.0 cm min -1 , in 3-B, with Vs = 2.5 cm min -1 and in figure 3-C, with Vs = 5.0 cm min -1 that only the Bratby Model oscillates in relation to the experimental data, emphasizing that in this experiment Voltan used aluminum sulfate as coagulant. In Figure 3-D, with Vs = 1.0 cm min -1 , in 3-E, with Vs = 1.5 cm min -1 and in Figure 3-F, with Vs = 3.0 cm min -1 , which evidences the experimental data of Constantino (2008), although he used ferric chloride as a coagulant and a different sedimentation rate from the study by Voltan (2007), it was possible to observe similar results in relation to the compared models.…”
Section: Comparison Between Methods and Modelssupporting
confidence: 78%
See 2 more Smart Citations
“…It can be identified in Figure 3-A, with Vs = 1.0 cm min -1 , in 3-B, with Vs = 2.5 cm min -1 and in figure 3-C, with Vs = 5.0 cm min -1 that only the Bratby Model oscillates in relation to the experimental data, emphasizing that in this experiment Voltan used aluminum sulfate as coagulant. In Figure 3-D, with Vs = 1.0 cm min -1 , in 3-E, with Vs = 1.5 cm min -1 and in Figure 3-F, with Vs = 3.0 cm min -1 , which evidences the experimental data of Constantino (2008), although he used ferric chloride as a coagulant and a different sedimentation rate from the study by Voltan (2007), it was possible to observe similar results in relation to the compared models.…”
Section: Comparison Between Methods and Modelssupporting
confidence: 78%
“…For the comparison of methods and models, experimental data from Dantas et al (2000), Voltan (2007), Constantino (2008) and Brito et al (2016) were used. Waters with the following characteristics were studied: Dantas, 2000, pH from 7.35 to 7.55, turbidity between 24 and 28 uT, apparent color between 175 and 215 uC, alkalinity from 23 to 27 mg.L of CaCO3; conductivity of 45.9 µS.cm; Constantino (2008), pH from 5.8 to 6.2, turbidity between 4 and 6 uT, apparent color between 100 and 150 uH, alkalinity from 14 to 18 mg.L of CaCO3; conductivity of 78.5 µS.cm; Brito et al, 2016, pH from 6.9 to 7.5, turbidity between 458 and 633.67 uT, apparent color between 720 and 750 uH, alkalinity from 42 to 43 mg.L -1 of CaCO3; conductivity of 106.67 µS.cm -1 .…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Two waters were prepared from stock solutions. For one, denominated type 1, 30 mg/L humic acid solution (Aldrich Chemical) was used to obtain a 50 PtCoas initial condition, according to Constantino (2008). For another, denominated type 2, kaolin solution (Fluka) was prepared to obtain 25 NTU, according to Pádua (1994) and Yukselen and Gregory (2004).…”
Section: Waters Studied and Coagulationmentioning
confidence: 99%
“…Van Benschoten & Edzwald apud Constantino (2008) pesquisaram a coagulação de ácido fúlvico como causador da cor, com sulfato de alumínio e cloreto polialumínio como coagulantes, variando pH entre 5 e 7. A partir dos resultados obtidos pelos pesquisadores, pôde-se notar que houve maior eficácia na remoção de carbono orgânico dissolvido -CODquando usados maiores valores de pH com dosagens excessivas de coagulante.…”
Section: Coagulação Floculaçãounclassified