2015
DOI: 10.1016/j.anifeedsci.2015.09.028
|View full text |Cite
|
Sign up to set email alerts
|

Ruminal disappearance of phosphorus and starch, reticuloruminal pH and total tract nutrient digestibility in dairy cows fed diets differing in grain processing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
15
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
10

Relationship

2
8

Authors

Journals

citations
Cited by 21 publications
(17 citation statements)
references
References 37 publications
1
15
0
Order By: Relevance
“…Gross energy of feed and feces was measured using an isoperibolic bomb calorimeter (C200, IKA ® -Werke GmbH & Co. KG, Staufen, Germany), with benzoic acid as the standard used to calibrate the instrument. Titanium dioxide was measured in feed and feces according to the method described by Khol-Parisini et al [18]; absorption was measured at 405 nm using a spectrophotometer (Hitachi U-3000, Metrohm INULA GmbH, Vienna, Austria). To measure total starch content of the TGS diet, the soluble TGS was leached out of the samples and treated with perchloric acid.…”
Section: Methodsmentioning
confidence: 99%
“…Gross energy of feed and feces was measured using an isoperibolic bomb calorimeter (C200, IKA ® -Werke GmbH & Co. KG, Staufen, Germany), with benzoic acid as the standard used to calibrate the instrument. Titanium dioxide was measured in feed and feces according to the method described by Khol-Parisini et al [18]; absorption was measured at 405 nm using a spectrophotometer (Hitachi U-3000, Metrohm INULA GmbH, Vienna, Austria). To measure total starch content of the TGS diet, the soluble TGS was leached out of the samples and treated with perchloric acid.…”
Section: Methodsmentioning
confidence: 99%
“…Gross energy content in feed, feces, and ileal digesta was determined using an isoperibolic bomb calorimeter (C200, IKA ® -Werke GmbH & Co. KG, Staufen, Germany), with benzoic acid as the standard used to calibrate the instrument. Titanium dioxide was measured in feed, feces, and ileal digesta according to the method described by Khol-Parisini et al [26]; absorption was measured at 405 nm using a spectrophotometer (Hitachi U-3000, Metrohm INULA GmbH, Vienna, Austria). Total starch content in feed, lyophilized ileal digesta and fecal samples as well as d - and l -lactate concentrations in fresh ileal digesta and fecal samples were determined using commercially available kits (Megazyme K-TSTA and K-DLATE, Wicklow, Ireland).…”
Section: Methodsmentioning
confidence: 99%
“…The starch content in ileal digesta and faeces was measured accordingly. Titanium dioxide was measured spectrophotometrically (Hitachi U-3000; Metrohm INULA GmbH) at 405 nm in feed, faeces and ileal digesta after Kjeldahl extraction (19) , whereas commercially available kits (Megazyme K-DLATE) were used to determine D-and L-lactate concentrations in fresh ileal digesta and faecal samples. Concentrations of SCFA in fresh ileal digesta and faecal samples were analysed using gas chromatography (13) .…”
Section: Chemical Analysismentioning
confidence: 99%