2013 IEEE International Ultrasonics Symposium (IUS) 2013
DOI: 10.1109/ultsym.2013.0103
|View full text |Cite
|
Sign up to set email alerts
|

RSNA/QIBA: Shear wave speed as a biomarker for liver fibrosis staging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

13
104
1

Year Published

2014
2014
2023
2023

Publication Types

Select...
5
3

Relationship

2
6

Authors

Journals

citations
Cited by 91 publications
(118 citation statements)
references
References 1 publication
13
104
1
Order By: Relevance
“…A marker of disease activity, proteinuria, has been mentioned in the literature as an influencing factor for kidney SWV [27], but we found no significant correlation between proteinuria and kidney SWV in our patients.…”
Section: Discussioncontrasting
confidence: 94%
See 1 more Smart Citation
“…A marker of disease activity, proteinuria, has been mentioned in the literature as an influencing factor for kidney SWV [27], but we found no significant correlation between proteinuria and kidney SWV in our patients.…”
Section: Discussioncontrasting
confidence: 94%
“…Another factor that influenced kidney SWV in our subjects was the depth of measurement; the decrease of the measured SWV was previously related to an increase in depthin studies performed on phantoms [26,27] or liver [28,29]. A marker of disease activity, proteinuria, has been mentioned in the literature as an influencing factor for kidney SWV [27], but we found no significant correlation between proteinuria and kidney SWV in our patients.…”
Section: Discussionmentioning
confidence: 47%
“…As shown by the studies on phantoms [129], the influence of depth on the estimation of elastic properties is not negligible. Furthermore, with curved transducers used in liver imaging, the angle affects the readings, with the best results being achieved when the ROI is straight ahead.…”
Section: Measurement Depthmentioning
confidence: 92%
“…An inter-laboratory study comparing shear wave velocities obtained with four different machines (Fibroscan, Philips iU22, ACUSON S2000 and Aixplorer) was conducted [129]. Working on elastic phantoms, a statistically significant difference in the SWS estimates among systems and depth of measurement in the phantom was shown, whereas no statistically significant differences were found among operators using the same or equivalent systems under the same conditions [129]. Similar results were obtained using phantoms with viscoelastic properties similar to those observed in normal and fibrotic liver [130].…”
Section: Studies On Phantomsmentioning
confidence: 99%
“…The first moment x m of the WSRx speckle signal at axial position z was calculated as (2) where x n is the lateral position of the n th A-line. The lateral peak x p (z) was determined from the maximum of the WSRx at a given axial position z.…”
Section: A Simulationsmentioning
confidence: 99%