2021
DOI: 10.3389/fphar.2021.676396
|View full text |Cite
|
Sign up to set email alerts
|

RRx-001 Radioprotection: Enhancement of Survival and Hematopoietic Recovery in Gamma-Irradiated Mice

Abstract: The present studies evaluate the in vivo prophylactic radioprotective effects of 1-bromoacetyl-3, 3-dinitroazetidine (RRx-001), a phase III anticancer agent that inhibits c-myc and downregulates CD-47, after total body irradiation (TBI), in lethally and sublethally irradiated CD2F1 male mice. A single dose of RRx-001 was administered by intraperitoneal (IP) injection 24 h prior to a lethal or sublethal radiation dose. When irradiated with 9.35 Gy, the dose lethal to 70% of untreated mice at 30 days (LD70/30), … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
7
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 34 publications
0
7
1
Order By: Relevance
“…The LD 50 for vehicle-treated animals was 9.22 (95% CI: 9.03-9.41); compared to our assumed 8.9 Gy. The DRF of RRx-001 was 1.07 (95% CI: 1.05-1.10) (32), which was lower than our DRF to detect; thus, actual power would have been decreased. The lethality slope on radiation dose was 41.6 (95% CI: 31.2-51.9), which was notably higher than our assumed slope of 25; this increase in precision would have increased actual power.…”
Section: Feasibility From Prospective Studycontrasting
confidence: 74%
See 4 more Smart Citations
“…The LD 50 for vehicle-treated animals was 9.22 (95% CI: 9.03-9.41); compared to our assumed 8.9 Gy. The DRF of RRx-001 was 1.07 (95% CI: 1.05-1.10) (32), which was lower than our DRF to detect; thus, actual power would have been decreased. The lethality slope on radiation dose was 41.6 (95% CI: 31.2-51.9), which was notably higher than our assumed slope of 25; this increase in precision would have increased actual power.…”
Section: Feasibility From Prospective Studycontrasting
confidence: 74%
“…The planning of one DRF experiment was retrospective in that the experiment was not designed using the sample size calculation ( 16 ). The other DRF experiment was prospective in that we used the sample size calculation when planning it ( 32 ). We note that for the prospective DRF experiment, we increased the calculated number of animals for the express purpose of evaluating the feasibility of using the sample size calculation.…”
Section: Feasibility Studiesmentioning
confidence: 99%
See 3 more Smart Citations