2015
DOI: 10.1007/s13738-015-0717-6
|View full text |Cite
|
Sign up to set email alerts
|

RPLC determination of acid dissociation constants and quantitative estimation for sulfasalazine

Abstract: disease-modifying antirheumatic drug (DMARD) used in the treatment of patients with rheumatoid arthritis. Clinical studies during the last two decades have provided evidence of the drug's efficacy in the treatment of both ulcerative colitis and Crohn's disease [1].Acid dissociation constant values (pK a ) are useful physicochemical measurements describing the extent of ionization of functional groups with respect to pH. This parameter is important in pharmaceutical drug discovery and development [2]. Various e… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(6 citation statements)
references
References 29 publications
(39 reference statements)
0
5
0
Order By: Relevance
“…The insoluble part in the prepared solution was removed by filtration. Finally, the solution obtained was prepared at different dilution rates according to the concentration in the calibration range specified for each compound [16,26,27].…”
Section: Analysis Of Tablet Solutionsmentioning
confidence: 99%
“…The insoluble part in the prepared solution was removed by filtration. Finally, the solution obtained was prepared at different dilution rates according to the concentration in the calibration range specified for each compound [16,26,27].…”
Section: Analysis Of Tablet Solutionsmentioning
confidence: 99%
“…Moreover, the proposed sensor was very facile and low-cost, indicating considerably feasible application for CTC and SSZ detection. [20] LC-fluorescence 0.0050-0.10 0.00050 [42] LC-MS 0.0010-0.30 0.0026 [24] CE 0.030-5.0 0.017 [26] Electrochemical sensor 0.046-25.77 0.026 [43] MIP-based ISEs ≥0.11 0.071 [44] N-CDs sensor 0.85-20.38 0.078 This work SSZ HPLC-dad 1-12 0.086 [22] LC-MS/MS 0.010-10.0 - [45] CE 0.050-0.50 0.0063 [27] Poly(3-methylthiophene) film modified GCE 30.0-128.0 10.0 [46] MWCNTCOOH-BA/SPCE 0.40-5.6 0.12 [47] Antimony film electrode 1.2-100 0.30 [48] N-CDs sensor 0.34-6.76 0.032 This work Note: MIP, molecularly imprinted polymer; ISEs, ion-selective electrodes; GCE, glassy carbon electrode; MWCNTCOOH-BA/SPCE, multiwalled carbon nanotubes/benzyl acetate modified screen-printed carbon electrode.…”
Section: Calibration Curvementioning
confidence: 99%
“…Up to now, several analytical techniques have been reported in the literature for CTC and SSZ detection including electrochemical , high performance liquid chromatography (HPLC) with UV/photodiode‐array or fluorescence detection , high performance liquid chromatography with mass spectrometry (HPLC‐MS) , capillary electrophoresis (CE) , and ultra‐high performance liquid chromatography coupled to tandem mass spectrometry (UPLC‐MS/MS) . Most of these methods mentioned are highly precise and sensitive, but not appropriate for routine analysis due to the requirements for sophisticated equipment, production of toxic effluents, and time‐consuming pretreatment of samples.…”
Section: Introductionmentioning
confidence: 99%
“…Reversed-phase liquid chromatography (RPLC) is the other preferred method to determine the pKa value of ionizable substances. This method is based on the different retention behavior of the ionized and neutral forms of drug molecules [13,14]. Among the advantages of this method is its necessity for a very small amount of the analyte and high purity of the sample is not required for the LC assays [15].…”
Section: Introductionmentioning
confidence: 99%