2015
DOI: 10.1016/j.jpba.2015.03.031
|View full text |Cite
|
Sign up to set email alerts
|

RP-HPLC method development for the simultaneous determination of timolol maleate and human serum albumin in albumin nanoparticles

Abstract: An isocratic high-performance liquid chromatographic method was developed and validated for the simultaneous determination of human serum albumin (HSA) and timolol in albumin nanoparticles. This method involved a reversed-phase-C18 column thermostated at 25 °C, UV detection at 276 nm, flow rate of 1.0 ml/min and a mobile phase compounded by 0.05% (v/v) trifluoroacetic acid in water/0.05% (v/v) trifluoroacetic acid in an acetonitrile (40:60, v/v) solution. The elution times for albumin and timolol were 1.84 ± 0… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
6
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 22 publications
(7 citation statements)
references
References 11 publications
1
6
0
Order By: Relevance
“…The inset of Figure 3 B showed that the fluorescence intensity had a linear relationship (R 2 = 0.9976) with HSA concentration in the concentration range of 0.15–2.5 μM, and the regression equation was Y = −313.35 X + 1064.3, where Y was the fluorescence intensity at 610 nm and X was the HA concentration. The limit of detection (LOD) of the proposed strategy was estimated to be 0.082 μM, which was lower and more rapid than the other methods [ 38 , 39 , 40 ]. Therefore, a simple, rapid, effective and sensitive method of HA determination was established.…”
Section: Resultsmentioning
confidence: 94%
“…The inset of Figure 3 B showed that the fluorescence intensity had a linear relationship (R 2 = 0.9976) with HSA concentration in the concentration range of 0.15–2.5 μM, and the regression equation was Y = −313.35 X + 1064.3, where Y was the fluorescence intensity at 610 nm and X was the HA concentration. The limit of detection (LOD) of the proposed strategy was estimated to be 0.082 μM, which was lower and more rapid than the other methods [ 38 , 39 , 40 ]. Therefore, a simple, rapid, effective and sensitive method of HA determination was established.…”
Section: Resultsmentioning
confidence: 94%
“…The TM high-performance-liquid-chromatography (HPLC) determination was performed as described by Boiero et al [56] with slight modifications. The HPLC system was composed by a separation module Waters Alliance 2695 and a Waters photodiode array 2996 (Barcelona, Spain).…”
Section: Tm Hplc Determinationmentioning
confidence: 99%
“…TIM is used as antihypertensive agent as well [32]. It was quantitatively determined by HPLC [31][32][33][34], 36] in bulk, pharmaceuticals and physiological fluids, UPLC methods [37] and an electrochmical one [38].…”
Section: Introductionmentioning