2002
DOI: 10.1093/jaoac/85.5.1136
|View full text |Cite
|
Sign up to set email alerts
|

Routine, High-Sensitivity, Cold Vapor Atomic Absorption Spectrometric Determination of Total Mercury in Foods after Low-Temperature Digestion

Abstract: A cold vapor atomic absorption spectrometric method was developed for the subnanogram-per-gram determination of total Hg in a wide variety of foods. Foods were weighed into 50 mL polypropylene centrifuge tubes and dried without charring at 55°C in a circulating oven. Samples were then digested at 58°C with HNO3, HCl, and H2O2. After matrix modification with solutions of 2% Mg(NO3)2, 0.01% Triton X-100, and Cu(II) at 10 μg/mL, samples were analyzed by using a CeTAC Technologies M-6000A dedicated Hg analyzer. Ba… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2004
2004
2020
2020

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 17 publications
(6 citation statements)
references
References 0 publications
0
6
0
Order By: Relevance
“…Analyses were performed using the reagents, instrumentation and methodology described in Dabeka et al (2002) . Briefly, after a low-temperature nitric/hydrochloric acid and hydrogen peroxide digestion of roughly 1 g fish tissue and dilution to 50 ml with water, measurements were made using a CETAC-6000A dedicated Hg analyser equipped with an ASX-500 autosampler and ADX autodilutor.…”
Section: Methodsmentioning
confidence: 99%
“…Analyses were performed using the reagents, instrumentation and methodology described in Dabeka et al (2002) . Briefly, after a low-temperature nitric/hydrochloric acid and hydrogen peroxide digestion of roughly 1 g fish tissue and dilution to 50 ml with water, measurements were made using a CETAC-6000A dedicated Hg analyser equipped with an ASX-500 autosampler and ADX autodilutor.…”
Section: Methodsmentioning
confidence: 99%
“…The combined effect of the two trends on the signal to background ratio as a plot of the ratio (DS/DB) and (1/F total ), 4 shows a very high correlation (r ¼ 0.9996), where DS and DB are the changes in the signal and background, respectively.…”
Section: Gas Flowsmentioning
confidence: 99%
“…Mercury and its organic compounds are well known neurotoxins, even at very low concentrations, and sensitive techniques such as cold vapour atomic absorption spectrometry (CV-AAS) [1][2][3][4][5][6][7][8][9] have been developed to measure low concentrations. The CV approach separates the analyte from the sample matrix and transports it to the atom cell with nearly 100% efficiency.…”
Section: Introductionmentioning
confidence: 99%
“…223,224 Optimised digestion procedures for specific applications seen include those for measuring Se in yeast 226 and Hg in various foods. 227 A rapid automated digestion apparatus was developed by Jacob and Berndt 9 with direct coupling for FAAS. Powdered samples suspended in 2.5 M HNO 3 passed through a Pt-Ir capillary heated electrically to 320 uC and the analysis was completed within 3 min.…”
Section: Digestionmentioning
confidence: 99%