2011
DOI: 10.1016/j.jms.2011.04.016
|View full text |Cite
|
Sign up to set email alerts
|

Rotational spectroscopy of iodobenzene and iodobenzene–neon with a direct digital 2–8GHz chirped-pulse Fourier transform microwave spectrometer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
44
0
1

Year Published

2012
2012
2024
2024

Publication Types

Select...
9

Relationship

7
2

Authors

Journals

citations
Cited by 66 publications
(46 citation statements)
references
References 63 publications
1
44
0
1
Order By: Relevance
“…A setting of 6% gain was the maximum that could be used before portions of the chirp were too large in amplitude to be recorded by the oscilloscope. As described by Neill et al [9], the amplifier introduces spurious components, particularly the sidebands 2m(t) and 3m(t), with m(t) being the original chirp. These spurious parts are low in intensity relative to the primary chirp.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…A setting of 6% gain was the maximum that could be used before portions of the chirp were too large in amplitude to be recorded by the oscilloscope. As described by Neill et al [9], the amplifier introduces spurious components, particularly the sidebands 2m(t) and 3m(t), with m(t) being the original chirp. These spurious parts are low in intensity relative to the primary chirp.…”
Section: Methodsmentioning
confidence: 99%
“…1 displays a scheme of our new chirped-pulse Fourier transform microwave spectrometer, COMPACT (compact-passage acquired coherence technique). It is a combination of the designs presented by Pate et al [1,9] and of that proposed by Grabow [7]. For experiment control, the program FTMW++ of Grabow (Leibniz-Universität Hannover) is employed.…”
Section: Methodsmentioning
confidence: 99%
“…The older, cavity based, method of Balle and Flygare [7] is usually more sensitive and is endowed with higher resolution, but its relative intensity performance is poor. On the other hand application of the more recent chirped-pulse technique [28] operating on the same expansion plume, but along a different axis of the cavity, allows faster recording time and considerably better relative intensity performance [27,29].…”
Section: Table 10mentioning
confidence: 99%
“…The response signal is still very weak so that * corresponding author; e-mail: kisiel@ifpan.edu.pl averaging over many hours or days is necessary. The original chirped pulse spectrometer design has been refined further [10,11] in order to overcome various instrumental challenges and this enabled many spectacular studies, such as those of the small water clusters [11][12][13][14].…”
Section: Introductionmentioning
confidence: 99%