2021
DOI: 10.1007/s11547-021-01355-7
|View full text |Cite
|
Sign up to set email alerts
|

Rotational positional error-corrected linear set-up margin calculation technique for lung stereotactic body radiotherapy in a dual imaging environment of 4-D cone beam CT and ExacTrac stereoscopic imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
11
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 9 publications
(12 citation statements)
references
References 31 publications
1
11
0
Order By: Relevance
“…This is due to several factors, including a lack of harmonization of imaging protocols, clinical validation issues, and an overall poor scientific quality of the studies in the field [ 43 , 45 , 103 , 104 ]. In line with this scenario, a RQS of 27.8% (range 22.2–38.9%) was calculated for the 8 articles retrieved in this review ( Table 2 ), consistent with other reviews focused on radiomics [ 105 , 106 , 107 , 108 , 109 , 110 , 111 , 112 , 113 , 114 , 115 , 116 , 117 , 118 , 119 , 120 ].…”
Section: Discussionsupporting
confidence: 85%
“…This is due to several factors, including a lack of harmonization of imaging protocols, clinical validation issues, and an overall poor scientific quality of the studies in the field [ 43 , 45 , 103 , 104 ]. In line with this scenario, a RQS of 27.8% (range 22.2–38.9%) was calculated for the 8 articles retrieved in this review ( Table 2 ), consistent with other reviews focused on radiomics [ 105 , 106 , 107 , 108 , 109 , 110 , 111 , 112 , 113 , 114 , 115 , 116 , 117 , 118 , 119 , 120 ].…”
Section: Discussionsupporting
confidence: 85%
“…And finally, compared with the Sentinel, Catalyst and ExacTrac, S-M_OPS-guided setup errors were smaller than those of Sentinel and Catalyst in all parts and directions. And S-M_OPS-guided setup errors were smaller than those of ExacTrac in the vast majority of the setup results (shown in Table 2 ) ( 20 22 , 30 , 31 ). For Sentinel and Catalyst, the setup accuracy is mainly affected by the following three factors.…”
Section: Discussionmentioning
confidence: 89%
“…In view of the above problems, many new setup methods have been proposed, including Catalyst ( 20 ), Sentinel ( 21 ), ExacTrac ( 7 , 22 24 ), etc. Catalyst and Sentinel use structured light to capture 3D surface of the patient, and register the acquired surface to the previous recorded one for setup error detection.…”
Section: Introductionmentioning
confidence: 99%
“…With such techniques, it is also possible to derive information directly from the images on the molecular and genomic characteristics of the tumor (radiogenomics) with the ultimate intent of extracting indications on aggressiveness, prognosis, and therapeutic response [ 77 , 133 , 201 , 202 , 203 , 204 , 205 , 206 , 207 , 208 , 209 , 210 , 211 , 212 , 213 , 214 , 215 , 216 , 217 , 218 , 219 , 220 , 221 , 222 , 223 , 224 , 225 , 226 , 227 , 228 , 229 , 230 , 231 , 232 ].…”
Section: Precision Medicine: Radiomics and Radiogenomics—the New Fron...mentioning
confidence: 99%