2020
DOI: 10.1016/j.scs.2020.102109
|View full text |Cite
|
Sign up to set email alerts
|

Rooftop extension as a solution to reach nZEB in building renovation. Application through typology classification at a neighborhood level

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(6 citation statements)
references
References 15 publications
0
5
0
Order By: Relevance
“…Nearly Zero Energy Buildings (NZEBs) are based on a group of regulations, energy polices, standards, and codes, which aim to ensure a higher improvement on building energy performance and also the implementation of on-site (or near-site) energy generation from renewable sources [37]. The objectives of the NZEBs are not only limited to new buildings [38], because existing buildings can be retrofitted considering energy saving measures and renewable generation.…”
Section: Literature Reviewmentioning
confidence: 99%
See 1 more Smart Citation
“…Nearly Zero Energy Buildings (NZEBs) are based on a group of regulations, energy polices, standards, and codes, which aim to ensure a higher improvement on building energy performance and also the implementation of on-site (or near-site) energy generation from renewable sources [37]. The objectives of the NZEBs are not only limited to new buildings [38], because existing buildings can be retrofitted considering energy saving measures and renewable generation.…”
Section: Literature Reviewmentioning
confidence: 99%
“…Each energy saving strategy must be planned, designed and modelled to estimate its impact on the building performance. Many authors have used the EnergyPlus software, initially to know if the strategies could achieve NZEB objectives or in the ideal scenario, if the modelling of strategies will achieve the expected zero balance [13,31,37]. Regarding onsite electricity generation, Homer PRO software is widely used by researchers to estimate the sizing, operation, economic costs, and other parameters, of power generation systems from renewable sources [42,43].…”
Section: Literature Reviewmentioning
confidence: 99%
“…The classification of residential typologies is based on the results of the PrestaRener project [39] and analysis carried out in previous projects by the research group SAVIArquitectura [40,41]. Eleven residential typologies were detected in both neighbourhoods.…”
Section: Residential Typologies and Building Parameters Definitionmentioning
confidence: 99%
“…Moreover, the use of electricity for heating and cooling can be profitably combined with installation of rooftop PV panels. Several studies focus on energy efficient buildings with rooftop PV in mild climates [19][20][21][22][23]. The progress towards zero energy buildings is equally significant in US and Canada [24,25].…”
Section: Introductionmentioning
confidence: 99%