Role of transoesophageal echocardiography in the diagnosis and management of aortic root abscess.

Abstract: Objective-To assess and compare the roles of transthoracic and transoesophageal echocardiography in the diagnosis and management of an aortic root abscess. Design-To select patients with echocardiographic diagnosis of aortic valve endocarditis with and without an aortic root abscess and correlate this with a retrospective review of surgical and necropsy data.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
34
0
8

Year Published

1998
1998
2021
2021

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 75 publications
(43 citation statements)
references
References 21 publications
1
34
0
8
Order By: Relevance
“…297 The sensitivity of TTE for detecting perivalvular abscess is low (18% to 63% in prospective and retrospective studies, respectively). 305,306 TEE dramatically improves the sensitivity for defining periannular extension of IE (76% to 100%) while retaining excellent specificity (95%) and positive and negative predictive values (87% and 89%, respectively). 54,307 When combined with spectral and color Doppler techniques, TEE can demonstrate the distinctive flow patterns of fistulas and pseudoaneurysms and can rule out communications from unruptured abscess cavities.…”
Section: Periannular Extension Of Infectionmentioning
confidence: 98%
“…297 The sensitivity of TTE for detecting perivalvular abscess is low (18% to 63% in prospective and retrospective studies, respectively). 305,306 TEE dramatically improves the sensitivity for defining periannular extension of IE (76% to 100%) while retaining excellent specificity (95%) and positive and negative predictive values (87% and 89%, respectively). 54,307 When combined with spectral and color Doppler techniques, TEE can demonstrate the distinctive flow patterns of fistulas and pseudoaneurysms and can rule out communications from unruptured abscess cavities.…”
Section: Periannular Extension Of Infectionmentioning
confidence: 98%
“…236 The sensitivity of TTE for detecting perivalvular abscess is low (18% to 63% in prospective and retrospective studies, respectively). 244,245 TEE dramatically improves sensitivity for defining periannular extension of IE (76% to 100%) while retaining excellent specificity (95%) and positive and negative predictive values (87% and 89%, respectively). 49,246 When combined with spectral and color Doppler techniques, TEE can demonstrate the distinctive flow patterns of fistulae and pseudoaneurysms and can rule out communications from unruptured abscess cavities.…”
Section: Periannular Extension Of Infectionmentioning
confidence: 98%
“…Ropień okołozastawkowy częściej występuje w IZW zastawki aortalnej (w 10-40% przypadków NVE) [3,[225][226][227] i często w przypadku PVE (56-100%) [3,6]. W przypadku zajęcia zastawki mitralnej ropnie okołozastawkowe zazwyczaj są zlokalizowane do tyłu lub bocznie od pierścienia zastawki [228].…”
Section: Okołozastawkowe Szerzenie Się Infekcyjnego Zapalenia Wsierdziaunclassified
“…Szczególnie użyteczne w ocenie powikłań okołozastawkowych są TEE, MSCT i PET/CT [103], podczas gdy czułość TTE wynosi < 50% (patrz rozdział 5.) [225][226][227][228]. Okołozastawkowe szerzenie się zakażenia jest często stwierdzane w systematycznie wykonywanejTEE.…”
Section: Okołozastawkowe Szerzenie Się Infekcyjnego Zapalenia Wsierdziaunclassified