2018
DOI: 10.1080/21556660.2018.1487446
|View full text |Cite
|
Sign up to set email alerts
|

Role of point of care Hb diagnostic devices in getting the right picture of anemia control: Tangi Rural Anemia Diagnostic Accuracy Study

Abstract: Objectives: To study the accuracy and reliability of two point of care devices (Hemocue 201 [HC201]) and Hemoglobin Colour Scale (HCS) with reference to automated laboratory analyser Sysmex XP 100 (LabSXP) and determine factors influencing their performances. To discuss certain design issues while ascertaining these parameters for its judicious use in both clinical context and disease burden studies.Methods: Reliability and accuracy statistics were calculated for four population subgroups that were selected ra… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 17 publications
(13 reference statements)
0
7
0
Order By: Relevance
“…TrueHb method involves a controlled prick using a loading gun unlike HemoCue that probably was responsible for better accuracy. Besides, accuracy parameters may also vary depending on the underlying Hb distribution, according to a recent study [23].…”
Section: Discussionmentioning
confidence: 99%
“…TrueHb method involves a controlled prick using a loading gun unlike HemoCue that probably was responsible for better accuracy. Besides, accuracy parameters may also vary depending on the underlying Hb distribution, according to a recent study [23].…”
Section: Discussionmentioning
confidence: 99%
“…The study population was drawn from a previously conducted study on anemia from our institute with 1,732 participants. 10 Reference individuals had been recruited using cluster sampling method from various villages and semi-urban regions across Khordha district of Odisha province, India, irrespective of their sex, religion, socioeconomic status, or any other demographic profile. All the participants were screened for history of smoking and alcohol intake, and had been duly excluded from the study.…”
Section: Patient Selectionmentioning
confidence: 99%
“…Blood sample that had been collected from the previous study and stored at À20°C after serum separation, was used. 10…”
Section: Patient Selectionmentioning
confidence: 99%
“…One of the interventions is to use digital hemoglobinometers (DH) as point-of-care tests (POCT) to estimate Hb status. Identification of anemia, especially in mild and moderate anemia remains undetected through clinical signs [ 5 - 7 ], thus use of DH in case of detection of anemia is more accurate and precise.…”
Section: Introductionmentioning
confidence: 99%