2012
DOI: 10.1016/j.ejrad.2011.11.015
|View full text |Cite
|
Sign up to set email alerts
|

Role of contrast-enhanced ultrasound in decision support for diagnosis and treatment of hepatic artery thrombosis after liver transplantation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
23
0
1

Year Published

2012
2012
2021
2021

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 33 publications
(24 citation statements)
references
References 19 publications
0
23
0
1
Order By: Relevance
“…Lack of visualization of the arterial tree, expected to be seen before portal enhancement, indicates complete arterial thrombosis with very high positive predictive values [10,32,99,131]. Identification of the arterial branches when conventional Doppler has failed [131], may allow subsequent targeted Doppler reassessment, which is needed to distinguish thrombosis from slow flow caused by vasoconstriction or splenic steal from postthrombotic/stenotic recanalization, tasks not achievable using CEUS alone.…”
Section: Image Interpretationmentioning
confidence: 99%
“…Lack of visualization of the arterial tree, expected to be seen before portal enhancement, indicates complete arterial thrombosis with very high positive predictive values [10,32,99,131]. Identification of the arterial branches when conventional Doppler has failed [131], may allow subsequent targeted Doppler reassessment, which is needed to distinguish thrombosis from slow flow caused by vasoconstriction or splenic steal from postthrombotic/stenotic recanalization, tasks not achievable using CEUS alone.…”
Section: Image Interpretationmentioning
confidence: 99%
“…Furthermore, CEUS has been accepted as a reliable technique for the identification of certain vascular complications. Therefore, it has been suggested by several studies that for the detection of HAT, a negative CEUS would avoid unnecessary invasive angiography (16,28,41). However, this approach cannot be applied to all cases.…”
Section: Discussionmentioning
confidence: 99%
“…Relevant data extracted from all 13 studies are summarized in table 1 (23)(24)(25)(26)(27)(28)(29)(30)(31)(32)(33)(34)(35). Only two studies involved more than 100 cases for CEUS evaluation.…”
Section: Study Characteristicsmentioning
confidence: 99%
“…CEUS has been reported to effectively improve flow visualization of the hepatic artery [4,19] and to shorten the scanning time in compared with CDUS 100% sensitivity and 97.8% accuracy for the detection of HAT [20].…”
Section: Discussionmentioning
confidence: 99%