2021
DOI: 10.3390/diagnostics11061058
|View full text |Cite
|
Sign up to set email alerts
|

Role of Contrast-Enhanced Ultrasound (CEUS) in Native Kidney Pathology: Limits and Fields of Action

Abstract: Gray scale ultrasound has an important diagnostic role in native kidney disease. Low cost, absence of ionizing radiation and nephrotoxicity, short performance time, and repeatability even at the bedside, are the major advantages of this technique. The introduction of contrast enhancement ultrasound (CEUS) in daily clinical practice has significantly reduced the use of contrast enhancement computed tomography (CECT) and contrast enhancement magnetic resonance (CEMR), especially in patients with renal disease. A… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

0
17
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 15 publications
(18 citation statements)
references
References 42 publications
(65 reference statements)
0
17
1
Order By: Relevance
“…Microbubbles (MBs) contain a core gas (generally sulfur hexafluoride or octafluoropropane) that has low diffusibility and solubility in water, as well as high vapor pressure, resulting in UCAs persisting inside the intravascular space. In response to ultrasound waves MBs contract and expand, reflecting the transducer with improved acoustic energy than passive reflectors and enabling increased backscattering signals (up to 30 dB) [1,2]. The non-linear oscillation pattern of MBs generates harmonic signals that help differentiate contrast signals from background tissues [3].…”
mentioning
confidence: 99%
See 4 more Smart Citations
“…Microbubbles (MBs) contain a core gas (generally sulfur hexafluoride or octafluoropropane) that has low diffusibility and solubility in water, as well as high vapor pressure, resulting in UCAs persisting inside the intravascular space. In response to ultrasound waves MBs contract and expand, reflecting the transducer with improved acoustic energy than passive reflectors and enabling increased backscattering signals (up to 30 dB) [1,2]. The non-linear oscillation pattern of MBs generates harmonic signals that help differentiate contrast signals from background tissues [3].…”
mentioning
confidence: 99%
“…Microbubbles are cleared from the vascular space approximately five to fifteen minutes following the injection of UCA. The internal gas is exhaled through the lungs, and the shell particles are metabolized by the liver [1,2]. A dual-image system is traditionally employed by CEUS, where half the screen displays a low mechanical index (MI) B-mode image for anatomical guidance while the other displays the image of the nonlinear MBs signal.…”
mentioning
confidence: 99%
See 3 more Smart Citations