2013
DOI: 10.1016/j.talanta.2013.07.072
|View full text |Cite
|
Sign up to set email alerts
|

Role of background observed in aptasensor with chemiluminescence detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
14
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 21 publications
(14 citation statements)
references
References 24 publications
0
14
0
Order By: Relevance
“…In 2014, Duan's group reported a nano-graphite-aptamer hybrid with the action of DNase I for the amplified monitoring of OTA (Wei et al, 2015 ). Meanwhile, a one-step chemiluminescent aptasensor was developed by Lee et al, using chemically initiated electron exchange luminescence (CIEEL) between a 1,1′-oxalyldiimidazole chemiluminescence (ODI-CL) reaction and the OTA aptamer conjugated with TEX615 (Park et al, 2013 ).…”
Section: G-quadruplex-based Detection Methods For Otamentioning
confidence: 99%
“…In 2014, Duan's group reported a nano-graphite-aptamer hybrid with the action of DNase I for the amplified monitoring of OTA (Wei et al, 2015 ). Meanwhile, a one-step chemiluminescent aptasensor was developed by Lee et al, using chemically initiated electron exchange luminescence (CIEEL) between a 1,1′-oxalyldiimidazole chemiluminescence (ODI-CL) reaction and the OTA aptamer conjugated with TEX615 (Park et al, 2013 ).…”
Section: G-quadruplex-based Detection Methods For Otamentioning
confidence: 99%
“…The rate of hybridization between MM 1, which is a double base mismatched ssDNA, and complementary probe-conjugated TEX615 was the slowest. 13), thrombin 19 ) in PBS buffer was faster than that in Tris-HCl buffer. The hybridization of MM 3 (5 0 -GTG GTG GAC TGC ATC-3 0 ) was faster than that of MM 2 (GTG GTG AAC TGC GTC-3 0 ) in the presence of complementary probe-conjugated TEX615.…”
Section: Determination Of Buffer Solution and Nanoparticle For Optimimentioning
confidence: 96%
“…13 Highly concentrated graphene oxide (GO, 500-700 nm, 5.5 mg ml À1 ) dispersed in water was purchased from Graphene Supermarket. We selected TEX615 as the uorescent dye used to label the complementary probe because its emission in the ODI-CL reaction has a higher intensity than other uorescent dyes (e.g., Texas Red, 6-FAM) widely utilized in conventional PO-CL or uorescence detection.…”
Section: Chemicals and Materialsmentioning
confidence: 99%
“…In order to confirm whether PSA aptamer-bound PSA emits light, we fabricated Fe 3 O 4 MWCNTs to remove free PSA aptamer, using the π-π stacking interaction between free aptamer and micro-or nano-particles (Cho et al, 2014;Choi et al, 2013;Park et al, 2013;Sheng et al, 2011;Yang et al, 2011) such as graphene oxide and MWCNTs, in aqueous solution based on the procedure shown in Fig. 3(b).…”
Section: Comparison Between Psa Aptamer 1 and Psa Aptamermentioning
confidence: 99%