2003
DOI: 10.1016/s0021-5155(03)00073-x
|View full text |Cite
|
Sign up to set email alerts
|

Rod-Driven Focal Macular Electroretinogram

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

2005
2005
2021
2021

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 12 publications
0
8
0
Order By: Relevance
“…m −2 . s −1 ), which is too dim to elicit a scattered light response from the periphery (Horiguchi et al ., 1991; Horiguchi and Miyaki, 1992; Chosi et al ., 2003). The reported mean amplitude of the b‐wave of the focal rod response recorded with this technique is 1.12 μ V, after averaging 200–400 responses.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…m −2 . s −1 ), which is too dim to elicit a scattered light response from the periphery (Horiguchi et al ., 1991; Horiguchi and Miyaki, 1992; Chosi et al ., 2003). The reported mean amplitude of the b‐wave of the focal rod response recorded with this technique is 1.12 μ V, after averaging 200–400 responses.…”
Section: Discussionmentioning
confidence: 99%
“…m −2 . s −1 , indicating that the effect of scattered light is minimal in these conditions (Horiguchi et al ., 1991; Horiguchi and Miyaki, 1992; Chosi et al ., 2003). Horiguchi et al .…”
Section: Introductionmentioning
confidence: 99%
“…Another technique used to record focal rod responses is the use of double-flashes to stimulate a 40 degree area that can isolate focal rod a-waves (Nusinowitz et al, 1995) or by using a small blue light (λ max = 470 nm) stimuli after dark-adaptation. (Choshi et al, 2003) Thus far, the clinical use of each technique to record scotopic responses from a focal area is limited.…”
Section: Focal Rod Ergsmentioning
confidence: 99%
“…(Miyake 1998 Their recording system for fmERGs was based on a fundus camera into which a focal stimulus system was integrated. Another system to record fmERGs was developed by Matsumoto et al (Choshi et al, 2003;Yamada et al, 2006) Their system is based on a slit-lamp microscope, and both the focal stimulus and fundus observation systems were integrated into the slit-lamp. With both systems, the examiner records the ERGs while monitoring the stimulus on the fundus either by an infrared television fundus camera or a slit-lamp-mounted infrared CCD camera.…”
mentioning
confidence: 99%
“…The focal response was calculated by subtracting the scattered light response from the original double peaked ERG b-wave response. Other methods used for recording a focal rod-ERG include suppressing the peripheral rods using a dim background, or using a using a very small five degree dim stimulus that produced no recordable scattered light component (Binns, & Margrain 2006;Choshi et al, 2003;Hood et al, 1998). While rod-isolated focal ERG responses can be obtained by these methods, the b-wave responses recorded are extremely small (<10 μV).…”
Section: Introductionmentioning
confidence: 99%