Robustness of single-electron pumps at sub-ppm current accuracy level

Abstract: We report on characterizations of single-electron pumps at the highest accuracy level, enabled by improvements of the small-current measurement technique. With these improvements a new accuracy record in measurements on single-electron pumps is demonstrated: 0.16 µA • A −1 of relative combined uncertainty was reached within less than 1 d of measurement time. Additionally, robustness tests of pump operation on a sub-ppm level revealed a good stability of tunable-barrier single-electron pumps against variations … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
126
3

Year Published

2017
2017
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 68 publications
(130 citation statements)
references
References 23 publications
1
126
3
Order By: Relevance
“…This 'null-voltage' approach was used in Ref. 7 and reduced the uncertainty due to the voltage calibration to a negligible level. In fact, it was attempted in the present study at NPL, but the JVS operation proved unreliable.…”
Section: Npl High-precision Measurement Setupmentioning
confidence: 99%
See 1 more Smart Citation
“…This 'null-voltage' approach was used in Ref. 7 and reduced the uncertainty due to the voltage calibration to a negligible level. In fact, it was attempted in the present study at NPL, but the JVS operation proved unreliable.…”
Section: Npl High-precision Measurement Setupmentioning
confidence: 99%
“…Thus far, bench-mark experiments such as those reported in Refs. 6 and 7 have required sophisticated cryogenic infrastructure; a helium-3 refrigerator 6 and a dilution refrigerator 7 . In the case of Ref.…”
Section: Introductionmentioning
confidence: 99%
“…[18][19][20][21][22] They are typically operated in cryogenic refrigerators at millikelvin temperatures and are able to accurately source currents of the order of 100 pA. The SET-generated current is transferred to current amplification and data acquisition instrumentation outside the refrigerator via low-noise cables.…”
Section: Cable Noise Measurementsmentioning
confidence: 99%
“…Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. uses a single AC signal with no applied source-drain bias [7][8][9][10][11]. This work has produced recent uncertainties as low as 1.6×10 −7 at 500 MHz (80 pA of current) [11].…”
Section: Introductionmentioning
confidence: 99%