2019
DOI: 10.3390/en12030340
|View full text |Cite
|
Sign up to set email alerts
|

Robust Mixed H 2 / H ∞ Controller Design for Energy Routers in Energy Internet

Abstract: In this paper, a class of mixed H2/H∞ controller is designed for an energy router (ER) within the scenario of an energy Internet (EI). The considered ER is assumed to have access with photovoltaic panels, wind turbine generators, micro-turbines, fuel cells, diesel engine generators, battery energy storage devices, flywheel energy storage devices, loads, and other ERs. Two types of control targets are considered. First, due to the access of large-scale renewable energy sources, the DC bus voltage deviation wit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
4
3

Relationship

2
5

Authors

Journals

citations
Cited by 16 publications
(3 citation statements)
references
References 32 publications
0
3
0
Order By: Relevance
“…The closed-loop system consists of an uncertain plant G(s) that has an n-input and m-output. The output system is represented as Yp(t), R(t) is a reference input, e(t) is an error signal of the closed-loop control system, C(s) is the tuning algorithm of the PID controller, W d and W n are weighting functions, and D(t) and N(t) are the disturbance and the noise, respectively [25]. The amount of disturbance and the noise can be determined through the infinity norm, as shown in Equation ( 5):…”
Section: Design Of H∞ Optimal Controllermentioning
confidence: 99%
“…The closed-loop system consists of an uncertain plant G(s) that has an n-input and m-output. The output system is represented as Yp(t), R(t) is a reference input, e(t) is an error signal of the closed-loop control system, C(s) is the tuning algorithm of the PID controller, W d and W n are weighting functions, and D(t) and N(t) are the disturbance and the noise, respectively [25]. The amount of disturbance and the noise can be determined through the infinity norm, as shown in Equation ( 5):…”
Section: Design Of H∞ Optimal Controllermentioning
confidence: 99%
“…There have been many further developments on the stochastic mixed H2false/H$$ {H}_2/{H}_{\infty } $$ control problem. The emphasis has been on the nonlinear systems and systems with multiplicative noise (see, e.g., References 2–8 and 9) as well as applications (see, e.g., References 10–12). However, the criteria in these further developments have remained quadratic.…”
Section: Introductionmentioning
confidence: 99%
“…Typically, an EI scenario can have access to the utility grid. Alternatively, when disconnected from the main power grid, multiple sub-grids interconnected via energy routers are able to function normally [6,7]. For the detailed definition, architecture and key technologies of EI, readers can refer to [8,9], and the references therein.…”
Section: Introductionmentioning
confidence: 99%