Robust Hybrid Flow Analyzer for Formaldehyde

Abstract: We report fully automated self-calibrating formaldehyde analyzers relying on a hybrid flow format and include operational scheme and design details. Long-term operation is made possible with the use of syringe pumps. Four identical analyzers were built and showed low LODs of 120 pptv or better (S/N = 3) and good linearity over 0-50 ppbv HCHO concentration range (r2 > 0.9960), all concentrations refer to 10 min averaging times. The analyzer can resume normal operation after shortterm power failure with at most … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
20
0

Year Published

2008
2008
2016
2016

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 24 publications
(22 citation statements)
references
References 31 publications
2
20
0
Order By: Relevance
“…Relatively stable at night, HCHO rapidly photolyzes after sunrise and serves as an important source for early morning radicals. Some of the highest HCHO levels in North America have been reported for the HGA, in particular the HSC area, ranging from ∼35 to 52 ppbv (Dasgupta et al, 2005;Eom et al, 2008). Airborne HCHO measurements in HGA likewise exceeded 30 ppbv on some occasions; terminal olefins were identified as the most important precursors .…”
Section: Introductionmentioning
confidence: 93%
“…Relatively stable at night, HCHO rapidly photolyzes after sunrise and serves as an important source for early morning radicals. Some of the highest HCHO levels in North America have been reported for the HGA, in particular the HSC area, ranging from ∼35 to 52 ppbv (Dasgupta et al, 2005;Eom et al, 2008). Airborne HCHO measurements in HGA likewise exceeded 30 ppbv on some occasions; terminal olefins were identified as the most important precursors .…”
Section: Introductionmentioning
confidence: 93%
“…The peak mixing ratio in the plume exceeds 30 ppb. Such peaks are hardly unprecedented, as the maximum HCHO concentration measured in the Ship Channel during TexAQS II was 52 ppb (Eom et al, 2008).…”
Section: Resultsmentioning
confidence: 99%
“…In flow injection analysis (FIA), the Hantzsch reaction has been applied to the analysis of air, [14][15][16][17] 15,18 have been employed. Amongst these, 2,4-pentanedione is recommended as the best reagent due to its reactivity at lower temperature and low sensitivity to interferences.…”
Section: Introductionmentioning
confidence: 99%
“…16 In a recent flow system, 2,4-pentanedione and ammonium acetate solutions were arranged to mix together in one of the syringes prior to a reaction with HCHO. 17 This flow system for the analysis of HCHO in air is based on the concept of a hybrid flow analyzer. 22 The system is more robust than the conventional FI system due to using syringe pumps.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation