Robust Feedback Control Design of Underactuated Robotic Hands with Selectively Lockable Switches for Amputees

Abstract: In recent years, reproduction of human mechanical hand with upgraded abilities is one of the major concerns. This paper addresses the problems of underactuated robotic hand with low cost design as it avoids electromyogram (EMG) sensors. The main goal is to balance the hand in the way, like grabbing, speed, and power, and provide a more robust and cost effective solution. All fingers have some mechanical consistency for picking up objects in a better way. A Flex sensor is attached to all fingers and it is inter… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2020
2020
2020
2020

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 10 publications
0
3
0
Order By: Relevance
“…Regarding the weight achieved in the prosthesis (less than 270 g) developed in this project, it is essential for the user in the adaptation process, to have prosthetic devices that have the ability to combine mechanical strength and low weight, being extremely important factors in the rehabilitation process. Thus, having a polymeric raw material for use in the three-dimensional printing process, such as PETG, which, despite being a light input, has values for printing with 25% infill, having density of 1.27 g/cm 3 , yield stress of 14.19 MPa, maximum tension of 20.68 MPa, and modulus of elasticity of 552.54 MPa.…”
Section: Device Buildingmentioning
confidence: 99%
See 2 more Smart Citations
“…Regarding the weight achieved in the prosthesis (less than 270 g) developed in this project, it is essential for the user in the adaptation process, to have prosthetic devices that have the ability to combine mechanical strength and low weight, being extremely important factors in the rehabilitation process. Thus, having a polymeric raw material for use in the three-dimensional printing process, such as PETG, which, despite being a light input, has values for printing with 25% infill, having density of 1.27 g/cm 3 , yield stress of 14.19 MPa, maximum tension of 20.68 MPa, and modulus of elasticity of 552.54 MPa.…”
Section: Device Buildingmentioning
confidence: 99%
“…The prosthesis can be functional or aesthetic, its main function, especially the hand, is to make a functional contribution to the user's manipulation ability, that is, provide the execution of activities that if it were not for the use of the device would not be possible to be performed efficiently and usefully. In addition, the prostheses also meet an aesthetic aspect in order to give a good appearance in the region of the removed limb [2][3][4][5]. Figure 1 shows some existing prostheses.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation