2018 13th IEEE International Conference on Industry Applications (INDUSCON) 2018
DOI: 10.1109/induscon.2018.8627068
|View full text |Cite
|
Sign up to set email alerts
|

Robust Design of Control Structure for Three-Phase Grid-Tied Inverters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 23 publications
0
4
0
Order By: Relevance
“…The resonant controller applied in the current control is widely used in grid tied systems due to the ability to eliminate the steady-state error between the controlled signal and its sinusoidal reference [16]. Although, unlike conventional PR controllers, this structure uses the grid-current (i o ) feedback in the comparison with current reference signal, for generating the error signal for compensation, and also directly in the HC control [15].…”
Section: System Descriptionmentioning
confidence: 99%
See 1 more Smart Citation
“…The resonant controller applied in the current control is widely used in grid tied systems due to the ability to eliminate the steady-state error between the controlled signal and its sinusoidal reference [16]. Although, unlike conventional PR controllers, this structure uses the grid-current (i o ) feedback in the comparison with current reference signal, for generating the error signal for compensation, and also directly in the HC control [15].…”
Section: System Descriptionmentioning
confidence: 99%
“…The current control is performed by a proportional-resonant (PR) controller with harmonic compensation (HC) with an alternative topology [15], using the grid-side current for feedback, resulting in low steady-state error [16].…”
Section: Introductionmentioning
confidence: 99%
“…The resonant controller applied in the current control is widely used in grid tied systems due to the ability to eliminate the steady-state error between the controlled signal and its sinusoidal reference (KRAEMER et al, 2018).…”
Section: System Descriptionmentioning
confidence: 99%
“…The VSI connection to the main grid must comply with requirements that ensures the safety and energy quality provided by the DG system, hence the VSI is connected to the grid by a low-pass filter which reduces the switching harmonics (KRAEMER et al, 2018).…”
Section: Introductionmentioning
confidence: 99%