2010
DOI: 10.1016/j.cnsns.2009.08.006
|View full text |Cite
|
Sign up to set email alerts
|

Robust decentralized controller design for UPFC using -synthesis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2011
2011
2016
2016

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 17 publications
0
7
0
Order By: Relevance
“…In this system, the first area is a single generator, but the second area is aggregation of a large number of generators and performs like an infinite bus. The system data are completely presented in [7]. To study the performance of system over a wide range of loading conditions, three different cases as nominal, light and heavy loading are considered and listed in Table 1.…”
Section: Illustrative Test Casesmentioning
confidence: 99%
See 2 more Smart Citations
“…In this system, the first area is a single generator, but the second area is aggregation of a large number of generators and performs like an infinite bus. The system data are completely presented in [7]. To study the performance of system over a wide range of loading conditions, three different cases as nominal, light and heavy loading are considered and listed in Table 1.…”
Section: Illustrative Test Casesmentioning
confidence: 99%
“…The detailed step-by-step procedure for computing of the controllers using structured singular value (l-based) technique is given in [16]. In [7] a systematic method to design UPFC controllers using mu-synthesis is presented. The robust synthesis problem is obtained in terms of the l-theory and the l-analysis.…”
Section: Stabilizer Design By Using Mu-synthesismentioning
confidence: 99%
See 1 more Smart Citation
“…According to the available literatures, the location of UPFC tends to be done empirically, if not arbitrarily, and the corresponding systematic investigation is not often enough [8]. The state-of-the-art UPFC analyses primarily focus on the application of stability control [8][9][10][11][12][13][14] in power systems.…”
Section: Introductionmentioning
confidence: 99%
“…A single-machine infinite bus system installed with UPFC is also considered as the second test case. The system data for the second test case are presented in [7]. The second test case is considered to evaluate the proposed MRAS tracking controller based on UPFC.…”
Section: Illustrative Test Casesmentioning
confidence: 99%