2015
DOI: 10.1016/j.athoracsur.2015.04.054
|View full text |Cite
|
Sign up to set email alerts
|

Robotic Total Arterial Off-Pump Coronary Artery Bypass Grafting: Seven-Year Single-Center Experience and Long-Term Follow-Up of Graft Patency

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
26
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 43 publications
(27 citation statements)
references
References 33 publications
1
26
0
Order By: Relevance
“…In addition, studies of on-pump TECAB, such as the multiinstitutional study by Argenziano and colleagues, reported longer operative times due to the need for peripheral cannulation and use of a cardiopulmonary circuit (20). Finally, perioperative outcomes such as ventilation time, ICU stay, and total hospitalization time were dependent on clinical pathways specific to each institution, and prolonged times may have been multi-factorial (10).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…In addition, studies of on-pump TECAB, such as the multiinstitutional study by Argenziano and colleagues, reported longer operative times due to the need for peripheral cannulation and use of a cardiopulmonary circuit (20). Finally, perioperative outcomes such as ventilation time, ICU stay, and total hospitalization time were dependent on clinical pathways specific to each institution, and prolonged times may have been multi-factorial (10).…”
Section: Discussionmentioning
confidence: 99%
“…After exclusion of duplicated studies and 546 irrelevant articles based on abstracts and titles, 126 studies remained for full-text evaluation. Of these, 44 studies met the inclusion criteria, including nine studies in the TECAB off-pump group (10)(11)(12)(13)(14)(15)(16)(17)(18); two studies in the TECAB on-pump group (19,20); and 16 studies in the robotic MIDCAB group (10,(21)(22)(23)(24)(25)(26)(27)(28)(29)(30)(31)(32)(33). One study provided separate data for both the TECAB offpump and robotic MIDCAB groups, and was included for analysis in both groups (10).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Therefore, data are of limited usefulness in daily clinical practice. 20 In a recent study of Yang et al, 7 long-term graft patency rate was investigated in 140 MIDCAB and 100 TECAB procedures. They were able to show excellent graft patency rates for each procedure.…”
Section: Discussionmentioning
confidence: 99%
“…For the timeframe of one to 5 years postoperatively, survival rates are reported to be over 90% in all studies. One study even reports 100% survival at 41 months (9). In another paper showing 93% survival at 5 years, all deaths on followup were non-cardiac in nature (4).…”
Section: Methodsmentioning
confidence: 99%