2021
DOI: 10.1007/s00381-021-05107-w
|View full text |Cite
|
Sign up to set email alerts
|

Robot-assisted stereoelectroencephalography electrode placement in twenty-three pediatric patients: a high-resolution analysis of individual lead placement time and accuracy at a single institution

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
7
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 28 publications
1
7
0
Order By: Relevance
“…Her electrode placement accuracy was excellent, with a mean target point error in line with previous reports [2] , [7] , [24] , [25] . Importantly, the accurate electrode placement in this case demonstrates the feasibility of accurate, safe electrode placement for someone of this age, and with very thin bone and an open fontanelle.…”
Section: Discussionsupporting
confidence: 87%
“…Her electrode placement accuracy was excellent, with a mean target point error in line with previous reports [2] , [7] , [24] , [25] . Importantly, the accurate electrode placement in this case demonstrates the feasibility of accurate, safe electrode placement for someone of this age, and with very thin bone and an open fontanelle.…”
Section: Discussionsupporting
confidence: 87%
“…Our error measurements in this very young cohort compare favorably with reports of error in older patients. 6,[39][40][41][42] The patients reported here had severe epilepsy with many seizures per day and developmental delay, and 3 had experienced regression because of their epilepsy. Three patients had genetic epilepsy, making this study group a particularly difficult-to-treat cohort.…”
Section: Discussionmentioning
confidence: 90%
“…Neurosurgical robots are currently commonly used in clinical practice, including the robotic stereotactic assistance (ROSA) and the Sinovation robotic system (Sinovation) (Zhao et al, 2020 ; Bonda et al, 2021 ). They are widely used in SEEG, deep brain stimulation, and other functional neurosurgical operations.…”
Section: Discussionmentioning
confidence: 99%
“…The effectiveness of SEEG depends on the quality of the electrode-implantation plan. Robot-assisted SEEG electrode implantation is increasingly being performed worldwide; numerous reports on its safety and accuracy have been published in the literature (Abel et al, 2018 ; Spyrantis et al, 2019 ; Bonda et al, 2021 ).…”
Section: Introductionmentioning
confidence: 99%