2018
DOI: 10.1080/13645706.2018.1544567
|View full text |Cite
|
Sign up to set email alerts
|

Robot-assisted percutaneous placement of K-wires during minimally invasive interventions of the spine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
16
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(17 citation statements)
references
References 26 publications
1
16
0
Order By: Relevance
“…We find a very high accuracy as shown in bone entry deviation data and angular errors (0.48 ± 0.44 mm, 0.94 ± 0.83° and 0.68 ± 0.58 mm, 0.87 ± 0.82°) in the axial and sagittal planes, respectively. This is in line with top performers among previously published material on bone entry deviation accuracy and superior in regard to angular errors (Table 3) [30][31][32][33][34][35][36] . This in turn resulted in a favorable simulated Gertzbein grading (100% accuracy), well in line with the vast majority of recent studies that typically report 98 -100% accuracy 34,[37][38][39][40][41] .…”
Section: Discussionsupporting
confidence: 89%
See 1 more Smart Citation
“…We find a very high accuracy as shown in bone entry deviation data and angular errors (0.48 ± 0.44 mm, 0.94 ± 0.83° and 0.68 ± 0.58 mm, 0.87 ± 0.82°) in the axial and sagittal planes, respectively. This is in line with top performers among previously published material on bone entry deviation accuracy and superior in regard to angular errors (Table 3) [30][31][32][33][34][35][36] . This in turn resulted in a favorable simulated Gertzbein grading (100% accuracy), well in line with the vast majority of recent studies that typically report 98 -100% accuracy 34,[37][38][39][40][41] .…”
Section: Discussionsupporting
confidence: 89%
“…Furthermore, our insertion times are also relatively short compared to other robotic systems. In studies reporting on comparable parts of the surgery, mean time per pedicle cannulation was 202-257 seconds 31,35 . These times do not entirely represent the time per pedicle screw, as no screw was inserted.…”
Section: Discussionmentioning
confidence: 99%
“…Therefore, significant superiority of robotic surgery in accuracy of screw placement compared with FH has been extensively demonstrated. 83 Despite many studies show the evidence of advantages of ro-botic surgery in timing, rates of infections and complications, there are evidences of the contrary. Indeed, some limitations of robotic spine surgery have been described.…”
Section: Discussionmentioning
confidence: 99%
“…Robots have been extensively employed in many surgical fields [10][11][12]. Robots have been used to assist in all aspects of spinal surgery, including improving the accuracy of spinal internal fixation, reducing exposure to radiation and improving operating room workflow [13][14][15]. The use of robots in assisted surgery enables surgeons to make significant improvements in coordination, three-dimensional visualization and fatigue reduction.…”
Section: Introductionmentioning
confidence: 99%