Abstract:The combination of RMFP with EMT provides an accurate method of navigation for spinal interventions such as facet joint punctures and intervertebral disc punctures.
“…breathing or movement). Due to the fact that most devices do not constantly provide information on the position of the needle, several electromagnetic devices for facilitating CT-guided punctures have recently been developed [14][15][16]. These devices offer an increased precision and a lower exposure to radiation for CT-guided punctures without restricting the accessibility of the patient.…”
“…breathing or movement). Due to the fact that most devices do not constantly provide information on the position of the needle, several electromagnetic devices for facilitating CT-guided punctures have recently been developed [14][15][16]. These devices offer an increased precision and a lower exposure to radiation for CT-guided punctures without restricting the accessibility of the patient.…”
“…Deux types de systèmes de repérage existent : ceux comme le système Imactis utilisé ici, où le récepteur élec-tromagnétique est situé dans un porte-aiguille, et ceux où le récepteur, extrêmement miniaturisé (et potentiellement plus sensible aux perturbations électromagnétiques), est placé à la pointe de l'aiguille [8,9,15,16]. Avec le système étudié ici (localisation du porte-aiguille et non de la pointe de l'aiguille), une erreur médiane de 3,7 mm par rapport au centre de la cible a été observée, ce qui est semblable aux résultats publiés sur fantôme pour certains systèmes optiques avec porte-aiguille, avec des erreurs mesurées entre 3,5 mm [13] et 4,6 mm [14] ; mais comme attendu, supérieur aux erreurs mesurées pour des systèmes élec-tromagnétiques avec senseur à l'extrémité de l'aiguille, rapportées entre 0,8 mm [9] et 1,6 mm [8].…”
Section: Discussionunclassified
“…Au cours de notre étude, la durée des procédures naviguées (médiane = 76 s) apparaît plus élevée que dans d'autres études testant sur fantôme un système électroma-gnétique : 28,6 s pour des ponctions avec une seule obliquité pour [9] ; 36 s pour 76 ponctions dans le plan pratiquées par seulement deux opérateurs pour [8]. Cependant, notre étude évalue des ponctions imposant systématiquement une double obliquité ; et à notre connaissance, c'est celle qui évalue les résultats du plus grand nombre d'opérateurs différents et sans expérience préalable.…”
Section: Discussionunclassified
“…Ainsi ces dernières années, des nouvelles technologies issues du domaine des gestes médico-chirurgicaux assistés par ordinateur ont vu le jour. Ces technologies ont été introduites avec succès en tomodensitométrie [7][8][9][10][11][12][13][14], où elles ont pour objectifs de faciliter le positionnement de l'aiguille, notamment pour des trajectoires en double obliquité, d'améliorer la précision des ponctions et de diminuer la dose d'irradiation.…”
“…Navigation and robotics in spine surgery laminae, 42 experimental injections using a robot arm guiding a flat-panel detector CT and electromagnetic navigation, 43 or remote-controlled injector for CT-guided punctures. 44 A further application of robotics is the biomechanical testing of spinal specimen and implants 35,45,46 or the support of physiotherapy training during rehabilitation from spinal injuries and surgery.…”
Spinal anatomy is complex and in close vicinity of vulnerable anatomical structures, such as nerve roots, spinal cord, and blood vessels, requiring high precision in surgical procedures, while the surgical exposure is limited and even more limited in percutaneous procedures. A high risk of misplaced implants and/or high intraoperative radiation exposure are the consequences. Spinal navigation techniques have been introduced to alleviate these problems. The majority of reports on navigation document its role in increasing implant-placement accuracy and reducing intraoperative radiation. The technology is increasingly finding acceptance amongst spinal surgeons. This however does not yet present the end of the road. Robotic applications could be regarded as a coherent continuation of spinal navigation. We reviewed the literature pertaining to spinal navigation, as well as novel and upcoming robotic applications for spinal surgery. For this purpose, a Medline search using the terms "robot" and "spine" and extensive cross-reference analysis (using Medline, Ovid, and Web of Science data banks) were performed. The goal was to provide an overview of present achievements and novel developments in this fast-growing research area. While a number of robotic techniques are under investigation, mainly to aid navigated screw placement, the SpineAssist/Renaissance system has cleared US Food and Drug Administration approval and is in relatively wide clinical use. Another robotic system, the da Vinci, is currently applied in an increasing number of cases under research protocols.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.