Risk of anastomotic leakage with two-row versus three-row manual circular staplers in colorectal anastomosis: a U.S. cohort study

Tongtong Wang,
Mordechai Sadowsky,
Rebekah Blakney
et al.

Abstract: Purposes To compare the risk of anastomotic leak (AL) between Ethicon manual circular staplers (two-row) versus Medtronic EEA™ circular stapler with Tri-Staple™ technology (three-row) and between Medtronic EEA™ circular stapler with DST™ Series technology (two-row) versus Tri-Staple™ technology. Methods A retrospective cohort study was conducted in adult patients who underwent a left-sided colorectal surgery 2019–2022 in U.S. Premier Healthcare Dat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 29 publications
0
5
0
Order By: Relevance
“…Furthermore, there is some heterogeneity in the studies because multicentre studies have been included, some of them with cases from large national databases or on-going clinical trials not designed to assess the difference in leakage rates among different devices [ 29 , 39 , 40 ]. At this point, it may be premature to state that MCS devices have worse outcomes than the newer PCS or TRCS devices primarily because there is no clear evidence in this regard [ 22 , 24 , 30 ].…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…Furthermore, there is some heterogeneity in the studies because multicentre studies have been included, some of them with cases from large national databases or on-going clinical trials not designed to assess the difference in leakage rates among different devices [ 29 , 39 , 40 ]. At this point, it may be premature to state that MCS devices have worse outcomes than the newer PCS or TRCS devices primarily because there is no clear evidence in this regard [ 22 , 24 , 30 ].…”
Section: Discussionmentioning
confidence: 99%
“…Sensitivity analysis did not detect significant problems in the PCS meta-analysis. However, in the case of TRCS, the work presented by Wang et al [ 30 ] was the one that introduced the greatest heterogeneity to the analysis, probably because sample size and the values recorded for leakage differed from those provided by the other three studies [ 12 , 28 , 29 ].…”
Section: Discussionmentioning
confidence: 99%