Risk factors of cardiac device infection: Glove contamination during device procedures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(8 citation statements)
references
References 18 publications
0
8
0
Order By: Relevance
“…The wound in which the pacemaker was placed was also cultured. 12 In 67% of cases, there was contamination of either the surgeon's or the assistant's gloves, with 42% of cases also having wound contamination. Interestingly though, no patients developed a clinical infection, either at 30 days postoperatively or within the first 2 years after pacemaker implantation.…”
Section: Analysis Corpmentioning
confidence: 99%
See 2 more Smart Citations
“…The wound in which the pacemaker was placed was also cultured. 12 In 67% of cases, there was contamination of either the surgeon's or the assistant's gloves, with 42% of cases also having wound contamination. Interestingly though, no patients developed a clinical infection, either at 30 days postoperatively or within the first 2 years after pacemaker implantation.…”
Section: Analysis Corpmentioning
confidence: 99%
“…11 Other level II studies looked at bacterial counts. A study by Kozon and colleagues 12 measured the bacterial count on surgeon's gloves and the assistant's gloves before handling a pacemaker for implantation. The wound in which the pacemaker was placed was also cultured.…”
Section: Analysis Corpmentioning
confidence: 99%
See 1 more Smart Citation
“…Glove change when draping the patient and before handling the generator may reduce risk for infection, although large-scale randomized clinical trials are lacking. 20 There is some support that bacterial glove contamination before handling the generator is common 66 and that double-gloving reduces the rate of inner glove perforation, but it is unclear whether microbial transmission and the rate of post-operative infectious complications are reduced. Non-powdered gloves may reduce the risk of infection by reducing local inflammation.…”
Section: Preventionmentioning
confidence: 99%
“…In addition, the heart pacemaker battery is not suitable for the human body because it may interact with human blood. 11 If the batteries are put into the man, the battery leak can contact the blood, which can trigger a toxic problem and death.…”
Section: Introductionmentioning
confidence: 99%