2002
DOI: 10.1016/s0920-3796(02)00144-8
|View full text |Cite
|
Sign up to set email alerts
|

Rigorous mcnp based shutdown dose rate calculations: computational scheme, verification calculations and application to ITER

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
39
0
1

Year Published

2011
2011
2021
2021

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 118 publications
(40 citation statements)
references
References 2 publications
0
39
0
1
Order By: Relevance
“…Shutdown dose rate calculations will be performed in the near future on the newly developed model. To be able to perform such calculations, the authors will rely on the on-going implementation of the so-called "rigorous-two-step" methodology [12] into TRIPOLI-4® [13]. Future work should also consider the optimization of the variance reduction scheme in TRIPOLI-4®, necessary to obtain reasonable statistical accuracy in the neutron flux meshes.…”
Section: Discussionmentioning
confidence: 99%
“…Shutdown dose rate calculations will be performed in the near future on the newly developed model. To be able to perform such calculations, the authors will rely on the on-going implementation of the so-called "rigorous-two-step" methodology [12] into TRIPOLI-4® [13]. Future work should also consider the optimization of the variance reduction scheme in TRIPOLI-4®, necessary to obtain reasonable statistical accuracy in the neutron flux meshes.…”
Section: Discussionmentioning
confidence: 99%
“…Shutdown dose rate calculations were performed utilizing the Rigorous 2-Step (R2S) approach [4]. The methodological approach for the present neutronics analysis is composed of three computational steps: 1) neutron transport calculations with the McDeLicious-11 Monte Carlo code [5] using the FENDL-3, Starter Library, Release 2 (FENDL-3/SLIB2) cross-section library [6], 2) activation calculations with the FISPACT-2007 inventory code [7] and EAF-2007 activation cross-section data, and 3) decay photon transport calculations with the Monte Carlo code MCNP5 [8].…”
Section: Calculation Code and Methodologymentioning
confidence: 99%
“…In this analysis only the contribution from specimens irradiated in HFTM was estimated and no detailed analysis for entire HFTM nor TC has been carried out so far. Therefore, this study has been devoted to obtain a detailed map of the radiation dose resulting from the whole HFTM and TC activated by utilizing the "Rigorous 2-Step (R2S)" approach developed at KIT [4]. The paper explains the calculation approach.…”
mentioning
confidence: 99%
“…Для этого в настоящее время проводятся расчёты дозы ней-тронного излучения, которую магнит получит в течение срока своей службы. Эти расчёты ведутся прямым одноступенчатым методом, разработанным коллективом ИТЭР и ENEA [22,23], и более точным двухсту-пенчатым методом, разработанным в Исследовательском центре Карлсруэ (FZK) [24]. Анализ мощности дозы от таких радиоактивных элементов, как Co, Cr и Nb, проводился для длительной работы токамака KSTAR.…”
Section: исследования в республике кореяunclassified