2002
DOI: 10.1016/s0928-0987(02)00166-5
|View full text |Cite
|
Sign up to set email alerts
|

Rheological characterization of Poloxamer 407 lidocaine hydrochloride gels

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

8
77
0
1

Year Published

2007
2007
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 112 publications
(91 citation statements)
references
References 26 publications
8
77
0
1
Order By: Relevance
“…The viscosities of F11 and Rozex ® were similar. Through this data, we also determined the pseudoplastic behavior of the formulations observed; the viscosity decreases as the shear rate increases (Pereira et al, 2013;Ricci et al, 2002). It is worth adding that, in general, formulations containing P407 gels offer the advantage of thixotropic behavior.…”
Section: Sol-gel Transition Temperaturementioning
confidence: 99%
See 2 more Smart Citations
“…The viscosities of F11 and Rozex ® were similar. Through this data, we also determined the pseudoplastic behavior of the formulations observed; the viscosity decreases as the shear rate increases (Pereira et al, 2013;Ricci et al, 2002). It is worth adding that, in general, formulations containing P407 gels offer the advantage of thixotropic behavior.…”
Section: Sol-gel Transition Temperaturementioning
confidence: 99%
“…It is worth adding that, in general, formulations containing P407 gels offer the advantage of thixotropic behavior. This is a desirable characteristic when the intention is to facilitate the administration and spreadability in open wounds in order to avoid friction of the gel, thus reducing the suffering of the patient (Ricci et al, 2002;Pereira et al, 2013). The viscosity values apparent at 20 s -1 for the thermosensitive gels were 4.4 Pa ± 1.2 for the F12 gel, 6.5 Pa ± 1.0 for the F11 gel and 7.2 Pa ± 0.6 for Rozex ® .…”
Section: Sol-gel Transition Temperaturementioning
confidence: 99%
See 1 more Smart Citation
“…Syringeability was evaluated on the basis of the ease with which the formulation under test passed through the needle and injectability was evaluated on the basis of the ease with which the formulation was injected into isolated extensor digitorum (chick muscle). [18] The extensor digitorum muscle from Gallus gallus domesticus was procured fresh from a reputable hatchery and the tissue weighing 4.5 g was excised. About 2 ml of formulation was drawn into a syringe with a 20 gauge needle and injected into the muscle.…”
Section: Measurement Of Viscosity and Gel Strengthmentioning
confidence: 99%
“…Once the mechanical characteristics of a material have been determined, it is often necessary to improve them in some manner to make the material suitable for the desired application. It is many ways to controlling the mechanical properties: altering the comonomer composition [9,10] increasing or decreasing the cross-linking density [11,12,13] and changing the conditions under which the polymer is formed [14,15].…”
Section: Introductionmentioning
confidence: 99%