2011
DOI: 10.1109/mdt.2011.131
|View full text |Cite
|
Sign up to set email alerts
|

RF Front-End Test Using Built-in Sensors

Abstract: International audienceThis article proposes a new class of sensors for built-in test in RF devices. These sensors are placed in close proximity to the DUT on the same substrate without being electrically connected to it. Instead, they monitor it by virtue of being subjected to the same process variations. The authors also describe other types of sensors they have studied, including DC probes, an envelope detector, and a current sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
4
3

Relationship

3
4

Authors

Journals

citations
Cited by 19 publications
(7 citation statements)
references
References 9 publications
0
7
0
Order By: Relevance
“…We have selected three popular alternative measurements that have been proposed in the literature for LNAs. In particular, we consider the dc voltages at the gate of M 3 and at the drain of M 1 , which can be monitored using dc probes [31], [32], and the root-mean-square (RMS) of the RF power at the output of the LNA, which can be monitored using an amplitude detector [32]- [35]. These three alternative measurements are obtained for the instances in the total fault model and the marginally functional instances.…”
Section: ) Specification Test Compactionmentioning
confidence: 99%
“…We have selected three popular alternative measurements that have been proposed in the literature for LNAs. In particular, we consider the dc voltages at the gate of M 3 and at the drain of M 1 , which can be monitored using dc probes [31], [32], and the root-mean-square (RMS) of the RF power at the output of the LNA, which can be monitored using an amplitude detector [32]- [35]. These three alternative measurements are obtained for the instances in the total fault model and the marginally functional instances.…”
Section: ) Specification Test Compactionmentioning
confidence: 99%
“…First, we record the output of the ED, then the input of the ED is switched to the output of the CS, in order to record the RMS value of the power supply current. The built-in test approach using envelope detectors and current sensors has been extensively studied in the literature [8][9][10][11][12]. It is cost-effective since only DC signals carrying RF information are extracted off-chip.…”
Section: B Bootstrapmentioning
confidence: 99%
“…Finally, alternate test is a generic technique that aims to map low-cost measurements to the RF performances [13,16,25,30], thus circumventing the need to measure directly the RF performances. Alternate test can also rely on information-rich, low-cost measurements obtained by built-in sensors [1].…”
Section: Introductionmentioning
confidence: 99%
“…To this end, it has been proposed to rely on non-intrusive built-in sensors that have the comparative advantage that let the design intact [1,2]. These non-intrusive sensors capitalize on the undesired phenomenon of process variations.…”
Section: Introductionmentioning
confidence: 99%