2021
DOI: 10.3389/fneur.2021.695202
|View full text |Cite
|
Sign up to set email alerts
|

RF Coil Setup for 31P MRSI in Tongue Cancer in vivo at 7 T

Abstract: Surgery for tongue cancer often results in a major loss in quality of life. While MRI may be used to minimise the volume of excised tissue, often the full tumour extent is missed. This tumour extent may be detected with metabolic imaging. One of the main reasons for the lack of metabolic information on tongue cancer would be the absence of an x-nuclear coil with the tongue as a focus target. Metabolic MRI through 31P MRSI is known as a powerful tool to non-invasively study elevated cell proliferation and distu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 36 publications
0
4
0
Order By: Relevance
“…[14] Although reduced in the mtLoop design, there is still a signal contribution from the tongue. However, if MRI of the tongue is also clinically relevant for specific applications, 27 a dedicated tongue coil would be preferred 28 …”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…[14] Although reduced in the mtLoop design, there is still a signal contribution from the tongue. However, if MRI of the tongue is also clinically relevant for specific applications, 27 a dedicated tongue coil would be preferred 28 …”
Section: Discussionmentioning
confidence: 99%
“…However, if MRI of the tongue is also clinically relevant for specific applications, 27 a dedicated tongue coil would be preferred. 28 Although current MR safety standards and guidelines do not explicitly mention IOCs, the guidelines for active implanted devices can be used to assess the safety of IOCs. 29 Here, we used a hotspot detection followed by temperature measurements as in Ref.…”
Section: Discussionmentioning
confidence: 99%
“…Even so, the method of using metabolite ratios is very robust, because it is less dependent on experimental variations, such as spatial sensitivity. Moreover, in comparison to widely available 1 H CSI, 31 P MRS is not hindered by the orders of magnitude larger signals of water and lipids that would obscure the metabolite detection, particularly in the presence of typical body motion and magnetic field inhomogeneities 43 . In none of the reported studies NOE enhancement or broadband proton decoupling was used.…”
Section: Discussionmentioning
confidence: 99%
“…Moreover, in comparison to widely available 1 H CSI, 31 P MRS is not hindered by the orders of magnitude larger signals of water and lipids that would obscure the metabolite detection, particularly in the presence of typical body motion and magnetic field inhomogeneities. 43 In none of the reported studies NOE enhancement or broadband proton decoupling was used. Although NOE enhancement can improve SNR, it may also influence metabolic ratios, which needs to be corrected for.…”
Section: Discussionmentioning
confidence: 99%