2020
DOI: 10.1051/e3sconf/202015501015
|View full text |Cite
|
Sign up to set email alerts
|

Reviews of Research on Mechanical Fault Diagnosis in GIS

Abstract: Gas Insulated Switchgear (GIS) has been widely used in recent years due to their advantages of small floor area, high reliability and good safety. It has arised a series of problems. At present, researchers at home and abroad have done more in-depth research on insulation fault, but research on mechanical fault is insufficient. Firstly, this paper reviews the research status of mechanical fault detection technology in GIS at home and abroad. Secondly, the aspect of the principles of mechanical fault in GIS, fa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 10 publications
0
3
0
Order By: Relevance
“…While GIS sound signals reflect their operating conditions, they also contain more redundant information. GIS sound signal fault information is mostly concentrated in the low frequency range [43]. In order to make the auditory periphery model more adaptable to the frequency characteristics of GIS sound signals, the number of frequency channels in the auditory saliency model needs to be further adjusted.…”
Section: Characteristic Frequency Adjustment For the Auditory Salienc...mentioning
confidence: 99%
“…While GIS sound signals reflect their operating conditions, they also contain more redundant information. GIS sound signal fault information is mostly concentrated in the low frequency range [43]. In order to make the auditory periphery model more adaptable to the frequency characteristics of GIS sound signals, the number of frequency channels in the auditory saliency model needs to be further adjusted.…”
Section: Characteristic Frequency Adjustment For the Auditory Salienc...mentioning
confidence: 99%
“…The partial discharge phenomenon mainly occurs in highvoltage electrical equipment, and the discharge phenomenon that occurs within the insulating device in the area and does not penetrate the voltage-applying conductor is called partial discharge [1,2]. It is different from the flashover breakdown phenomenon, which is mainly due to the deterioration of the insulation, resulting in a small localized breakdown.…”
Section: Introductionmentioning
confidence: 99%
“…Due to the rise in the partial discharge (PD), the decomposed SF 6 gas inside the GIS reacts with a trace amount of moisture or oxygen at high voltage and high current. And this adversely affects the insulating ability of the GIS, prevents recombination into SF 6 itself, and forms various oxidation by‐products 19,20 . Therefore, insulation deterioration, breakdown, and explosion of GIS due to the increase in these by‐products and PD can have a major effect on human life, industrial safety, and environmental sustainability caused by large scale power outages or fires.…”
Section: Introductionmentioning
confidence: 99%