2007
DOI: 10.1016/j.aca.2007.08.021
|View full text |Cite
|
Sign up to set email alerts
|

Review: Recent applications of scanning electrochemical microscopy to the study of charge transfer kinetics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
37
0
6

Year Published

2009
2009
2024
2024

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 56 publications
(44 citation statements)
references
References 150 publications
1
37
0
6
Order By: Relevance
“…Enhanced sensitivity was obtained when these measurements were carried out in total internal reflection mode which allowed the direct optical measurements of the accumulation of base electrolytes at the ITIES upon externally applied potentials [168][169][170]. The application of scanning electrochemical microscopy (SECM) has been extended to studies of electron transfer across the ITIES [171][172][173]. The kinetics of electron transfer and ion transfer is determined directly by SECM.…”
Section: Other Techniquesmentioning
confidence: 99%
“…Enhanced sensitivity was obtained when these measurements were carried out in total internal reflection mode which allowed the direct optical measurements of the accumulation of base electrolytes at the ITIES upon externally applied potentials [168][169][170]. The application of scanning electrochemical microscopy (SECM) has been extended to studies of electron transfer across the ITIES [171][172][173]. The kinetics of electron transfer and ion transfer is determined directly by SECM.…”
Section: Other Techniquesmentioning
confidence: 99%
“…The SECM versatility allows electrochemical studies at almost any interface (i.e. liquid/solid, liquid/liquid and gas/solid interfaces) [25][26][27][28][29][30][31]. As a result, SECM has been applied in various fields such as biology to study the respiratory chain of Escherichia coli [32] or in forensic sciences to image human fingerprints [33,34].…”
Section: Introductionmentioning
confidence: 99%
“…Essa espécie é gerada no decorrer dos experimentos pelo substrato ou pelo microeletrodo (Lu, Wang et al, 2007). Nos casos em que o microeletrodo é o "gerador", o substrato opera como "coletor" devido à grande diferença de área a eficiência de coleta é, via de regra, unitária desde que a espécie gerada seja estável.…”
Section: Figuraunclassified
“…O mapeamento da superfície é realizado mantendo-se fixa a posição do microeletrodo na direção z em região muito próxima à superfície do substrato imerso em um eletrólito contendo um mediador redox previamente adicionado ou que seja liberado pela superfície em estudo. Alterando-se a posição do microeletrodo nas direções x e y e monitorando-se a corrente obtida, pode-se obter informação sobre o fluxo ou liberação de material através do substrato, sobre a topografia do substrato como consequência da variação da distância entre o substrato e o microeletrodo, ou ainda construir um mapa da reatividade da superfície com os dados coletados (Bard e Mirkin, 2001;Lu, Wang et al, 2007;Baltes e Heinze, 2009;Okunola, Nagaiah et al, 2009).…”
Section: Obtenção De Imagens Utilizando Secmunclassified
See 1 more Smart Citation