2021
DOI: 10.1097/ftd.0000000000000901
|View full text |Cite
|
Sign up to set email alerts
|

Review of the Preanalytical Errors That Impact Therapeutic Drug Monitoring

Abstract: Purpose: Preanalytical errors comprise the majority of testing errors experienced by clinical laboratories and significantly impact the accuracy of therapeutic drug monitoring (TDM).Methods: Specific preanalytical factors in sample timing, collection, transport, processing, and storage that lead to errors in TDM were reviewed. We performed a literature search using several scientific databases including PubMed, ScienceDirect, Scopus, Web of Science, and ResearchGate for human studies published in the English l… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 99 publications
(149 reference statements)
0
6
0
Order By: Relevance
“…76 Typically, blood sampling from an intravenous line should be avoided. Therefore, if drugs are administered intravenously, 79 blood samples for TDM should not be collected from the same intravenous line. Drug contamination may lead to high drug concentrations.…”
Section: Determination Of Serum Drug Concentration Preanalytical Cond...mentioning
confidence: 99%
“…76 Typically, blood sampling from an intravenous line should be avoided. Therefore, if drugs are administered intravenously, 79 blood samples for TDM should not be collected from the same intravenous line. Drug contamination may lead to high drug concentrations.…”
Section: Determination Of Serum Drug Concentration Preanalytical Cond...mentioning
confidence: 99%
“…54 Care should be taken to prevent specimen contamination by the infusion solution, which would lead to erroneous results and possible misinterpretation. 53…”
Section: Analysis Of Drug Concentrationsmentioning
confidence: 99%
“…54 Care should be taken to prevent specimen contamination by the infusion solution, which would lead to erroneous results and possible misinterpretation. 53 The second critical issue is the processing and storage of specimens, which is particularly true for aminoglycoside testing and analyses of some members of the beta-lactam family. Appropriate storage times under different conditions reported in manufacturer documents or the literature are provided in Table 3.…”
Section: Preanalytics and Analytical Techniques To Determine Antibiot...mentioning
confidence: 99%
See 2 more Smart Citations