2020
DOI: 10.1016/j.measurement.2020.107624
|View full text |Cite
|
Sign up to set email alerts
|

Review of real-time three-dimensional shape measurement techniques

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
43
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 87 publications
(43 citation statements)
references
References 144 publications
0
43
0
Order By: Relevance
“…It can be concluded that the measurement model instituted by (10) and (11) is effective and accurate, and the influence of the projection distortion on the measurement is reduced, the final measurement accuracy meets the requirements of straightening the gear shaft. Both the accuracy of the calibration board and the detected accuracy of the light stripe center affect the accuracy of the measurement results, as the accuracy of the calibration board is 1μm, then the detected errors of pixel coordinates of the light stripe center are critical factors affecting the accuracy, and the detection accuracy of light stripe center is related to the parameters of the laser and the imaging characteristics of the object surface [24].…”
Section: Resultsmentioning
confidence: 99%
“…It can be concluded that the measurement model instituted by (10) and (11) is effective and accurate, and the influence of the projection distortion on the measurement is reduced, the final measurement accuracy meets the requirements of straightening the gear shaft. Both the accuracy of the calibration board and the detected accuracy of the light stripe center affect the accuracy of the measurement results, as the accuracy of the calibration board is 1μm, then the detected errors of pixel coordinates of the light stripe center are critical factors affecting the accuracy, and the detection accuracy of light stripe center is related to the parameters of the laser and the imaging characteristics of the object surface [24].…”
Section: Resultsmentioning
confidence: 99%
“…The incidence of the second movement typology, instead, is directly related to the number of scans required to reconstruct the entire anatomy and the time spent to reposition the scanner around the target surface. Thus, a real-time single-shot 3D scanning technique would be preferable for most situations [ 17 ]. Therefore, the popular structured light method based on the phase-shifting technique cannot be considered properly suitable for human body acquisition, since it needs to project at least three images.…”
Section: Discussionmentioning
confidence: 99%
“…For this reason, in this section, an overview is presented, focusing on techniques at the base of commercial devices and research approaches. A main taxonomy could classify these techniques into three categories [ 17 ]: time-of-flight (TOF) techniques, passive image-based techniques, and active image-based techniques (structured light, SL).…”
Section: 3d Scanning Technologiesmentioning
confidence: 99%
See 2 more Smart Citations