2016
DOI: 10.1088/1748-0221/11/01/p01007
|View full text |Cite
|
Sign up to set email alerts
|

Review of hybrid pixel detector readout ASICs for spectroscopic X-ray imaging

Abstract: ASIC, we demonstrate that the spectroscopic information contained in the incoming photon beam can be recovered by the implementation in hardware of an algorithm whereby the signal from a single photon is reconstructed and allocated to the pixel with the largest deposition.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

2
151
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 177 publications
(162 citation statements)
references
References 71 publications
(60 reference statements)
2
151
0
Order By: Relevance
“…Photon counting detector (PCD) based computed tomography (PCCT) is an emerging imaging technique and substantial progress has been reported in recent years by different researchers (Tümer et al, 2000, Schlomka et al, 2008, Shikhaliev, 2008b, Shikhaliev, 2008a, Iwanczyk et al, 2009, Kappler et al, 2010, Taguchi and Iwanczyk, 2013, Persson et al, 2014, Bennett et al, 2014, Roessl and Proksa, 2007, Ballabriga et al, 2016). PCDs measure individual photons and their associated energy, rather than the integrated charges generated by all measured photons, as occurs with an energy-integrating detector (EID).…”
Section: Introductionmentioning
confidence: 99%
“…Photon counting detector (PCD) based computed tomography (PCCT) is an emerging imaging technique and substantial progress has been reported in recent years by different researchers (Tümer et al, 2000, Schlomka et al, 2008, Shikhaliev, 2008b, Shikhaliev, 2008a, Iwanczyk et al, 2009, Kappler et al, 2010, Taguchi and Iwanczyk, 2013, Persson et al, 2014, Bennett et al, 2014, Roessl and Proksa, 2007, Ballabriga et al, 2016). PCDs measure individual photons and their associated energy, rather than the integrated charges generated by all measured photons, as occurs with an energy-integrating detector (EID).…”
Section: Introductionmentioning
confidence: 99%
“…The Medipix3 chip implemented a programmable ACS and featured small 55 lm pixel sizes, using ACS to sum 2 9 2 groups to produce an effective pixel pitch of 110 lm. 17 The Medipix3 chip is notable because it was an early design that produced very good spectroscopic results, but the count rate capability of this chip was well below the needs of diagnostic CT. 18 Recently, progress has been made in this regard, with a detector using 0.1 mm CdTe pixels that implements ACS. The authors show that the performance of charge summing improves performance at up to 250 Mcps/ mm 2 for a material decomposition task.…”
Section: Introductionmentioning
confidence: 99%
“…Reconstruction yields an energy- weighted image of linear attenuation coefficients. This loss of energy information results in some major limitations to current CT technologies, including poor soft tissue contrast and reduced accuracy of mass attenuation measurements [2, 3]. …”
Section: Introductionmentioning
confidence: 99%