Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2014
DOI: 10.1080/10826076.2014.941265
|View full text |Cite
|
Sign up to set email alerts
|

Review of Advances in Planar Radiochromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 69 publications
0
8
0
Order By: Relevance
“…TLRC is also termed as "planar radiochromatography" because paper, impregnated paper (instant thin layer chromatography or ITLC) as well as thin layer stationary phases are employed. [50] …”
Section: Tlc-msmentioning
confidence: 97%
See 1 more Smart Citation
“…TLRC is also termed as "planar radiochromatography" because paper, impregnated paper (instant thin layer chromatography or ITLC) as well as thin layer stationary phases are employed. [50] …”
Section: Tlc-msmentioning
confidence: 97%
“…[50] The following are the examples of studies that involved TLC analysis of radiolabeled pesticides.…”
Section: Tlc-msmentioning
confidence: 99%
“…Resolution is degraded to some extent by the spatial arrangement of the detector and layer and radioactivity detection is not widely used with HPTLC layers for complex separations. The classic method of detecting labeled compounds by autoradiography, in which the dry layer is placed in contact with photographic (X-ray) film and subsequently developed and scanned, is still in use, but is no longer common practice [56]. The in situ detection of labeled compounds with a sodium iodide scintillation detector, linear analyzer, or phosphor imaging detector represent the current state-of-the-art [56,89,90].…”
Section: Radiochromatography Scannersmentioning
confidence: 99%
“…The classic method of detecting labeled compounds by autoradiography, in which the dry layer is placed in contact with photographic (X-ray) film and subsequently developed and scanned, is still in use, but is no longer common practice [56]. The in situ detection of labeled compounds with a sodium iodide scintillation detector, linear analyzer, or phosphor imaging detector represent the current state-of-the-art [56,89,90]. Instruments are available from companies specializing in radiochemistry equipment including Camberra Industries ( accumulated for quantitative measurements.…”
Section: Radiochromatography Scannersmentioning
confidence: 99%
See 1 more Smart Citation